| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16.5–19 | 158 / 158 |
| EER2 · BTU/Wh | 8–9.8 | 158 / 158 |
| HSPF2 · BTU/Wh | 8.1–9 | 158 / 158 |
| Cooling capacity · BTU/h | 54,000–58,000 | 158 / 158 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 59,000–63,500 | 54 / 158 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 50,500–57,500 | 158 / 158 |
| Heating capacity at 5°F / −15°C · BTU/h | 41,000–46,000 | 158 / 158 |
| COP at 5°F / −15°C | 1.86–2.1 | 158 / 158 |
| Equipment / loop type | HP - Split System | 158 / 158 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 158 / 158 |
| Compressor staging | Continuously variable | 158 / 158 |
| Connected capability | No | 158 / 158 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X61M24A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 215677986 | 18.50 | 9.00 | 42000 | 2.02 | EPA 3973321 → |
EA*5X61M24A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 215677996 | 18.50 | 9.00 | 42000 | 2.02 | EPA 3973328 → |
EA*5X61M24A*+WALLCON+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 215678006 | 18.50 | 9.00 | 42000 | 2.00 | EPA 3973346 → |
EA*5X61M24A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 215678016 | 18.50 | 9.00 | 42000 | 2.02 | EPA 3973352 → |
EA*5X61M24A*+WALLCON+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 215678026 | 18.50 | 9.00 | 41500 | 2.02 | EPA 3973359 → |
EA*5X60M24A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 215682576 | 18.50 | 9.00 | 42000 | 1.90 | EPA 3977527 → |
EA*5X60M24A*+WALLCON+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 215682586 | 18.50 | 8.50 | 41000 | 2.04 | EPA 3977539 → |
EA*5X60M24A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 215682606 | 18.50 | 9.00 | 42000 | 1.90 | EPA 3977560 → |
EA*5X60M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 215682616 | 18.50 | 9.00 | 41500 | 1.90 | EPA 3977569 → |
EA*5X60M24A*+WALLCON+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 215682626 | 18.50 | 9.00 | 41500 | 2.02 | EPA 3977574 → |
EA*5X61M24A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 215682656 | 18.50 | 9.00 | 42000 | 2.02 | EPA 3977936 → |
EA*5X61M24A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 215682686 | 18.50 | 9.00 | 42000 | 2.02 | EPA 3978027 → |
EA*5X61M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 215682696 | 18.50 | 9.00 | 42000 | 2.02 | EPA 3978031 → |
EA*5X61M24A*+WALLCON+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 215682706 | 18.50 | 9.00 | 41500 | 2.02 | EPA 3978042 → |
EVM5X60M21A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 215682856 | 18.50 | 9.00 | 45000 | 2.08 | EPA 3978215 → |
EVD5X60M21A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 215683046 | 18.50 | 9.00 | 44500 | 2.08 | EPA 3978227 → |
EVD5X60M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 215683096 | 18.50 | 9.00 | 44500 | 2.08 | EPA 3978277 → |
EVD5X60M24A*+WALLCON+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 215683106 | 18.50 | 9.00 | 44500 | 2.10 | EPA 3978284 → |
EVD5X61M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 215683226 | 18.50 | 9.00 | 44500 | 2.08 | EPA 3978297 → |
EVM5X60M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 215682906 | 18.50 | 9.00 | 44500 | 2.08 | EPA 3978342 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →