H5H0V48*K*AAA*
Deluxe 20 VS Heat Pump · source records, page 9
376 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for H5H0V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 376 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–19.5 | 376 / 376 |
| EER2 · BTU/Wh | 9–10.5 | 376 / 376 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 376 / 376 |
| Cooling capacity · BTU/h | 43,500–49,000 | 376 / 376 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–50,000 | 376 / 376 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 41,000–47,500 | 376 / 376 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,000–37,600 | 376 / 376 |
| COP at 5°F / −15°C | 1.92–2.2 | 376 / 376 |
| Equipment / loop type | HP - Split System | 376 / 376 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 376 / 376 |
| Compressor staging | Continuously variable | 376 / 376 |
| Connected capability | No | 376 / 376 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVM5X48M21A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 215675386 | 18.50 | 9.00 | 36400 | 2.00 | EPA 3969052 → |
EVM5X48M21A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 215675396 | 18.50 | 9.00 | 36400 | 2.00 | EPA 3969069 → |
EVM5X49M21A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 215675606 | 18.50 | 9.00 | 37200 | 1.98 | EPA 3969140 → |
EVM5X48M21A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 215675446 | 18.50 | 9.00 | 36600 | 2.00 | EPA 3969191 → |
EVM5X48M21A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 215675456 | 18.50 | 9.00 | 36400 | 2.00 | EPA 3969196 → |
EVM5X49M21A*+WALLCON+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 215675616 | 18.50 | 9.00 | 37400 | 1.98 | EPA 3969223 → |
EVM5X49M21A*+WALLCON+ furnace: *96CTN0801714B*Cold climate designationAHRI reference: 215675646 | 18.50 | 9.00 | 36200 | 2.02 | EPA 3969249 → |
EVM5X48M21A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 215675476 | 18.50 | 9.00 | 36400 | 2.00 | EPA 3969284 → |
EVM5X48M21A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 215675486 | 18.50 | 9.00 | 36400 | 2.00 | EPA 3969291 → |
EVM5X49M21A*+WALLCON+ furnace: *80CSU1002120A*Cold climate designationAHRI reference: 215675516 | 18.50 | 9.00 | 36800 | 2.00 | EPA 3969327 → |
EVM5X49M21A*+WALLCON+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 215675536 | 18.50 | 9.00 | 37200 | 2.00 | EPA 3969339 → |
EVM5X60M21A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 215675766 | 18.50 | 9.00 | 36800 | 2.00 | EPA 3969365 → |
EVM5X60M21A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 215675786 | 18.50 | 9.00 | 37200 | 1.98 | EPA 3969391 → |
EVM5X60M21A*+WALLCON+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 215675796 | 18.50 | 9.00 | 37400 | 1.98 | EPA 3969402 → |
EVM5X60M24A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 215675906 | 18.50 | 9.00 | 36800 | 2.00 | EPA 3969423 → |
EVD5X48M21A*+WALLCON+ furnace: *80CSU0802120A*Cold climate designationAHRI reference: 215676106 | 18.50 | 9.00 | 36400 | 2.00 | EPA 3969818 → |
EVD5X48M21A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 215676126 | 18.50 | 9.00 | 36400 | 2.00 | EPA 3969859 → |
EVD5X48M21A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 215676146 | 18.50 | 9.00 | 36400 | 2.00 | EPA 3969880 → |
EVD5X48M21A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 215676166 | 18.50 | 9.00 | 36400 | 2.00 | EPA 3969939 → |
EVD5X48M24A*+WALLCON+ furnace: *80CSU1002120A*Cold climate designationAHRI reference: 215676186 | 18.50 | 9.00 | 36600 | 2.02 | EPA 3969967 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.