H5H0V48*K*AAA*
Deluxe 20 VS Heat Pump · source records, page 16
376 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for H5H0V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 376 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–19.5 | 376 / 376 |
| EER2 · BTU/Wh | 9–10.5 | 376 / 376 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 376 / 376 |
| Cooling capacity · BTU/h | 43,500–49,000 | 376 / 376 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–50,000 | 376 / 376 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 41,000–47,500 | 376 / 376 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,000–37,600 | 376 / 376 |
| COP at 5°F / −15°C | 1.92–2.2 | 376 / 376 |
| Equipment / loop type | HP - Split System | 376 / 376 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 376 / 376 |
| Compressor staging | Continuously variable | 376 / 376 |
| Connected capability | No | 376 / 376 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X48M21A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 215674037 | 17.50 | 9.00 | 34200 | 2.06 | EPA 3967996 → |
EA*5X48M21A*+WALLCON+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 215674047 | 17.50 | 9.00 | 34200 | 2.06 | EPA 3967999 → |
EA*5X48M21A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 215674117 | 17.50 | 9.00 | 34200 | 2.06 | EPA 3968068 → |
EA*5X48M21A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 215674127 | 17.50 | 9.00 | 34000 | 2.04 | EPA 3968093 → |
EA*5X48M21A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 215674147 | 17.50 | 9.00 | 34000 | 2.04 | EPA 3968103 → |
EA*5X60M24A*+WALLCON+ furnace: *80CSU1002120A*Cold climate designationAHRI reference: 215674167 | 17.50 | 9.00 | 33600 | 2.06 | EPA 3968117 → |
EA*5X61M21A*+WALLCON+ furnace: *96CTN0801714B*Cold climate designationAHRI reference: 215674437 | 17.50 | 9.00 | 33600 | 2.08 | EPA 3968171 → |
EA*5X61M24A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 215674517 | 17.50 | 9.00 | 33800 | 2.08 | EPA 3968261 → |
EA*5X61M24A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 215674560 | 17.50 | 9.00 | 34200 | 2.06 | EPA 3968288 → |
EA*5X60M24A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 215674217 | 17.50 | 9.00 | 33600 | 2.08 | EPA 3968444 → |
EA*5X60M24A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 215674237 | 17.50 | 9.00 | 34000 | 2.06 | EPA 3968471 → |
EA*5X61M21A*+WALLCON+ furnace: *80CSU1002120A*Cold climate designationAHRI reference: 215674317 | 17.50 | 9.00 | 33800 | 2.06 | EPA 3968569 → |
EA*5X61M21A*+WALLCON+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 215674337 | 17.50 | 9.00 | 34000 | 2.06 | EPA 3968582 → |
EA*5X61M21A*+WALLCON+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 215674387 | 17.50 | 9.00 | 34200 | 2.06 | EPA 3968634 → |
EA*5X61M21A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 215674407 | 17.50 | 9.00 | 34200 | 2.06 | EPA 3968656 → |
EVM5X48M21A*+WALLCON+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 215675406 | 17.50 | 9.00 | 37000 | 1.98 | EPA 3969147 → |
EVD5X48M21A*+WALLCON+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 215676136 | 17.50 | 9.00 | 37000 | 1.98 | EPA 3969867 → |
EA*5X48M21A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 215681296 | 17.50 | 9.00 | 34200 | 2.06 | EPA 3974528 → |
EA*5X48M21A*+WALLCON+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 215681306 | 17.50 | 9.00 | 34000 | 2.04 | EPA 3974537 → |
EA*5X48M21A*+WALLCON+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 215681326 | 17.50 | 9.00 | 33800 | 2.06 | EPA 3975340 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.