H5H0V48*K*AAA*
Deluxe 20 VS Heat Pump
376 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for H5H0V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 376 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–19.5 | 376 / 376 |
| EER2 · BTU/Wh | 9–10.5 | 376 / 376 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 376 / 376 |
| Cooling capacity · BTU/h | 43,500–49,000 | 376 / 376 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–50,000 | 376 / 376 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 41,000–47,500 | 376 / 376 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,000–37,600 | 376 / 376 |
| COP at 5°F / −15°C | 1.92–2.2 | 376 / 376 |
| Equipment / loop type | HP - Split System | 376 / 376 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 376 / 376 |
| Compressor staging | Continuously variable | 376 / 376 |
| Connected capability | No | 376 / 376 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
FCMA5B60L0D*+WALLCONCold climate designationAHRI reference: 215675346 | 19.50 | 9.50 | 33000 | 2.20 | EPA 3969022 → |
EVM5X61M24A*+WALLCON+ furnace: *80CSU0802120A*Cold climate designationAHRI reference: 215675956 | 19.50 | 9.00 | 36600 | 2.10 | EPA 3969466 → |
EVM5X61M24A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 215675986 | 19.50 | 9.50 | 36600 | 2.10 | EPA 3969499 → |
EVM5X61M24A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 215675996 | 19.50 | 9.50 | 36600 | 2.10 | EPA 3969508 → |
EVM5X61M24A*+WALLCON+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 215676006 | 19.50 | 9.50 | 36600 | 2.10 | EPA 3969515 → |
EVM5X61M24A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 215676056 | 19.50 | 9.50 | 36600 | 2.12 | EPA 3970013 → |
EVM5X61M24A*+WALLCON+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 215676066 | 19.50 | 9.50 | 36800 | 2.12 | EPA 3970020 → |
EVM5X61M24A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 215676076 | 19.50 | 9.50 | 36600 | 2.12 | EPA 3970029 → |
EVM5X61M24A*+WALLCON+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 215676086 | 19.50 | 9.50 | 36600 | 2.12 | EPA 3970043 → |
EVD5X61M21A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 215676746 | 19.50 | 9.50 | 36600 | 2.12 | EPA 3970413 → |
EVD5X61M21A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 215676756 | 19.50 | 9.50 | 36600 | 2.12 | EPA 3970428 → |
EVD5X61M21A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 215676816 | 19.50 | 9.50 | 36800 | 2.12 | EPA 3970571 → |
EVD5X61M21A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 215676836 | 19.50 | 9.50 | 36800 | 2.12 | EPA 3970593 → |
EVD5X61M24A*+WALLCON+ furnace: *80CSU0802120A*Cold climate designationAHRI reference: 215676846 | 19.50 | 9.00 | 36600 | 2.10 | EPA 3970608 → |
EVD5X61M24A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 215676876 | 19.50 | 9.50 | 36600 | 2.10 | EPA 3970795 → |
EVD5X61M24A*+WALLCON+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 215676886 | 19.50 | 9.50 | 36600 | 2.10 | EPA 3970814 → |
EVD5X61M24A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 215676926 | 19.50 | 9.50 | 36800 | 2.12 | EPA 3971338 → |
EVD5X61M24A*+WALLCON+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 215676936 | 19.50 | 9.50 | 36800 | 2.12 | EPA 3971349 → |
EVD5X61M24A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 215676946 | 19.50 | 9.50 | 36800 | 2.12 | EPA 3971358 → |
EVD5X61M24A*+WALLCON+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 215676956 | 19.50 | 9.50 | 36600 | 2.12 | EPA 3971363 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →