Airquest / AIR-SOURCE HEAT PUMP

D5CUHAH30AAK+KSAIC0701230

Crossover Heat Pump · source records, page 10

342 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range8.1–9BTU/Wh
Cooling capacity28,600–31,200BTU/h

Each efficiency range summarizes published EPA records for D5CUHAH30AAK+KSAIC0701230. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 342 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17342 / 342
EER2 · BTU/Wh9.5–10.5342 / 342
HSPF2 · BTU/Wh8.1–9342 / 342
Cooling capacity · BTU/h28,600–31,200342 / 342
Heating capacity at 47°F / 8.3°C · BTU/h35,800–37,400342 / 342
Heating capacity at 17°F / −8.3°C · BTU/h20,800–21,600342 / 342
Heating capacity at 5°F / −15°C · BTU/h32,000–33,400342 / 342
COP at 5°F / −15°C1.75–2342 / 342
Equipment / loop typeHP - Split System342 / 342
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)342 / 342
Compressor stagingContinuously variable342 / 342
Connected capabilityNo342 / 342

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
ESH5X42M12A*+ furnace: *80VTL0902120B*Cold climate designationAHRI reference: 21848873815.508.50324001.82EPA 4632273
ESH5X42M12A*+ furnace: *80VSL1352422B*Cold climate designationAHRI reference: 21848868915.508.50324001.84EPA 4632322
ESH5X42M12A*+ furnace: *80VSL0902120B*Cold climate designationAHRI reference: 21848867515.508.50324001.82EPA 4632336
ESH5X42M12A*+ furnace: *80MS(N,L)1102420A*Cold climate designationAHRI reference: 21848862415.508.50324001.84EPA 4632385
F5MA5*30L*B*Cold climate designationAHRI reference: 21848854015.508.50322001.80EPA 4632455
F5MA5*36L*B*Cold climate designationAHRI reference: 21848853315.509.00320001.96EPA 4632462
F5MA5*42L*C*Cold climate designationAHRI reference: 21848852615.509.00320001.98EPA 4632469
FHMA5*30L*B*Cold climate designationAHRI reference: 21848851915.508.50322001.80EPA 4632476
FHMA5*36L*B*Cold climate designationAHRI reference: 21848851215.509.00320001.96EPA 4632483
FHMA5*42L*C*Cold climate designationAHRI reference: 21848850515.509.00320001.98EPA 4632490
ESH5X36M12A*+ furnace: *80VTL1102122B*Cold climate designationAHRI reference: 21848927215.508.50326001.82EPA 4633139
ESH5X36M12A*+ furnace: *80MSU0401712A*Cold climate designationAHRI reference: 21848922315.508.50326001.82EPA 4633202
ESH5X36M12A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 21848949815.508.50326001.80EPA 4633355
ESH5X36M12A*+ furnace: *95MSU0802120A*Cold climate designationAHRI reference: 21848944215.508.50326001.82EPA 4633390
ESH5X36M12A*+ furnace: *96VSN1202422B*Cold climate designationAHRI reference: 21848942115.508.50326001.80EPA 4633404
ESH5X36M12A*+ furnace: *96VSN1002120B*Cold climate designationAHRI reference: 21848941415.508.50326001.80EPA 4633411
ESH5X36M12A*+ furnace: *97VTN1002120A*Cold climate designationAHRI reference: 21848954015.508.50326001.80EPA 4633462
ESH5X36M12A*+ furnace: OMV112K14ACold climate designationAHRI reference: 21848956815.508.50326001.84EPA 4633482
EA*5X43M21A*+ furnace: *80MS(N,L)0701716A*Cold climate designationAHRI reference: 21849001615.509.00322001.98EPA 4633589
EA*5X43M21A*+ furnace: *80MS(N,L)0451714A*Cold climate designationAHRI reference: 21849000215.509.00322001.96EPA 4633603