D5CUHAH24AAK+KSAIC0701230
Crossover Heat Pump · source records, page 2
511 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for D5CUHAH24AAK+KSAIC0701230. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 511 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 511 / 511 |
| EER2 · BTU/Wh | 10–11 | 511 / 511 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 511 / 511 |
| Cooling capacity · BTU/h | 22,600–25,000 | 511 / 511 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,200–25,800 | 511 / 511 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 16,800–18,700 | 511 / 511 |
| Heating capacity at 5°F / −15°C · BTU/h | 18,700–20,600 | 511 / 511 |
| COP at 5°F / −15°C | 1.85–2.06 | 511 / 511 |
| Equipment / loop type | HP - Split System | 511 / 511 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 511 / 511 |
| Compressor staging | Continuously variable | 511 / 511 |
| Connected capability | No | 511 / 511 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
FMA5X24**AL*Cold climate designationAHRI reference: 218486257 | 17.50 | 9.00 | 19000 | 2.02 | EPA 4631938 → |
FM(C,U)5Z36**AL*Cold climate designationAHRI reference: 218486236 | 17.50 | 9.00 | 19000 | 2.04 | EPA 4631945 → |
FM(C,U)5Z30**AL*Cold climate designationAHRI reference: 218486229 | 17.50 | 9.00 | 19000 | 2.04 | EPA 4631952 → |
EA*5X25M17A*+ furnace: *80MS(N,L)0701412A*Cold climate designationAHRI reference: 218484812 | 17.00 | 8.50 | 18900 | 1.94 | EPA 4629392 → |
EA*5X36M17A*+ furnace: *80MS(N,L)0701712A*Cold climate designationAHRI reference: 218485110 | 17.00 | 8.50 | 19300 | 1.92 | EPA 4629639 → |
EA*5X25M17A*+ furnace: *92MSN0801716A*Cold climate designationAHRI reference: 218484868 | 17.00 | 8.50 | 18900 | 1.94 | EPA 4629858 → |
EA*5X37M21A*+ furnace: *92MSN1002120A*Cold climate designationAHRI reference: 218485415 | 17.00 | 8.50 | 18800 | 1.92 | EPA 4630230 → |
EA*5X37M21A*+ furnace: *92MSN0801716A*Cold climate designationAHRI reference: 218485401 | 17.00 | 8.50 | 18700 | 1.94 | EPA 4630244 → |
EA*5X37M21A*+ furnace: *80MS(N,L)0701712A*Cold climate designationAHRI reference: 218485338 | 17.00 | 8.50 | 18800 | 1.94 | EPA 4630307 → |
EA*5X37M21A*+ furnace: *97VTN1002122A*Cold climate designationAHRI reference: 218487454 | 17.00 | 9.00 | 18900 | 2.02 | EPA 4630741 → |
EA*5X37M21A*+ furnace: *97VTN1002120A*Cold climate designationAHRI reference: 218487447 | 17.00 | 8.50 | 18700 | 1.92 | EPA 4630748 → |
EA*5X37M21A*+ furnace: *97VTN0802120A*Cold climate designationAHRI reference: 218487440 | 17.00 | 8.50 | 18900 | 1.92 | EPA 4630755 → |
EA*5X37M21A*+ furnace: *97VTN0801716A*Cold climate designationAHRI reference: 218487433 | 17.00 | 9.00 | 18900 | 2.02 | EPA 4630762 → |
EA*5X37M21A*+ furnace: *97VTN0601716A*Cold climate designationAHRI reference: 218487426 | 17.00 | 8.50 | 18800 | 1.92 | EPA 4630769 → |
EA*5X37M21A*+ furnace: *96VTN1002122B*Cold climate designationAHRI reference: 218487419 | 17.00 | 9.00 | 18900 | 2.02 | EPA 4630776 → |
EA*5X37M21A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 218487412 | 17.00 | 8.50 | 18700 | 1.92 | EPA 4630783 → |
EA*5X37M21A*+ furnace: *96VTN0802120B*Cold climate designationAHRI reference: 218487405 | 17.00 | 8.50 | 18900 | 1.92 | EPA 4630790 → |
EA*5X37M21A*+ furnace: *96VTN0801716B*Cold climate designationAHRI reference: 218487398 | 17.00 | 9.00 | 18900 | 2.02 | EPA 4630797 → |
EA*5X37M21A*+ furnace: *96VTN0601716B*Cold climate designationAHRI reference: 218487391 | 17.00 | 8.50 | 18800 | 1.92 | EPA 4630804 → |
EA*5X37M21A*+ furnace: *95MSU0802120A*Cold climate designationAHRI reference: 218487363 | 17.00 | 8.50 | 18700 | 1.92 | EPA 4630832 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →