B5H6S31*K*AAA*
MAINLINE 16 SEER2 HP · source records, page 2
38 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for B5H6S31*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 38 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 38 / 38 |
| EER2 · BTU/Wh | 11.7–13 | 38 / 38 |
| HSPF2 · BTU/Wh | 7.8–8 | 38 / 38 |
| Cooling capacity · BTU/h | 27,400–29,400 | 38 / 38 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 29,200–30,600 | 38 / 38 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 17,300–18,200 | 38 / 38 |
| Heating capacity at 5°F / −15°C · BTU/h | 13,100–14,000 | 38 / 38 |
| COP at 5°F / −15°C | 2–2.06 | 38 / 38 |
| Equipment / loop type | HP - Split System | 38 / 38 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 38 / 38 |
| Compressor staging | Single stage | 38 / 38 |
| Connected capability | No | 38 / 38 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X43M21A*+ furnace: *92MSN1002122A*AHRI reference: 218209881 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4584162 → |
EA*5X43M21A*+ furnace: *92MSN1002120A*AHRI reference: 218209879 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4584164 → |
EA*5X43M21A*+ furnace: *92MSN0802120A*AHRI reference: 218209877 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4584166 → |
EA*5X43M21A*+ furnace: *80MSU0802120A*AHRI reference: 218209835 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4584168 → |
EA*5X43M21A*+ furnace: *80MSU0601716A*AHRI reference: 218209833 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4584170 → |
EA*5X43M21A*+ furnace: *80VSL1102122B*AHRI reference: 218209829 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4584172 → |
EA*5X43M21A*+ furnace: *80MS(N,L)1102120A*AHRI reference: 218209821 | 15.50 | 8.00 | 14000 | 2.04 | EPA 4584174 → |
EA*5X43M21A*+ furnace: *80MS(N,L)0902120A*AHRI reference: 218209819 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4584176 → |
EA*5X43M21A*+WALLCON+ furnace: *80CSU0802120B*AHRI reference: 218209803 | 15.50 | 8.00 | 13900 | 2.04 | EPA 4584178 → |
EA*5X43M21A*+WALLCON+ furnace: *80CSU0401712B*AHRI reference: 218209799 | 15.50 | 8.00 | 13900 | 2.06 | EPA 4584180 → |
EA*5X37M21A*+ furnace: *97VTN1002122A*AHRI reference: 218209777 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4584182 → |
EA*5X37M21A*+ furnace: *96VTN1002122B*AHRI reference: 218209767 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4584184 → |
EA*5X37M21A*+ furnace: *95MSU1002122A*AHRI reference: 218209743 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4584186 → |
F5MA5*30L*B*AHRI reference: 218210694 | 15.50 | 7.80 | 13400 | 2.00 | EPA 4584250 → |
FEVB0036**+NAVA53601CKAHRI reference: 218210692 | 15.50 | 7.80 | 13400 | 2.00 | EPA 4584252 → |
FEVA0036**+NAVA53601CKAHRI reference: 218210690 | 15.50 | 7.80 | 13400 | 2.00 | EPA 4584254 → |
FCMA5B36L0C*+WALLCONAHRI reference: 218210688 | 15.50 | 7.80 | 13100 | 2.05 | EPA 4584256 → |
FMA5L30**AL*AHRI reference: 218210712 | 15.20 | 8.00 | 13800 | 2.00 | EPA 4584240 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →