Airquest / AIR-SOURCE HEAT PUMP

B5H6S24*K*AAA*

MAINLINE 16 SEER2 HP · source records, page 7

182 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–24,400BTU/h

Each efficiency range summarizes published EPA records for B5H6S24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 182 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5182 / 182
EER2 · BTU/Wh11.7–13182 / 182
HSPF2 · BTU/Wh7.8–8.5182 / 182
Cooling capacity · BTU/h22,200–24,400182 / 182
Heating capacity at 47°F / 8.3°C · BTU/h21,600–24,000182 / 182
Heating capacity at 17°F / −8.3°C · BTU/h14,200–15,200182 / 182
Heating capacity at 5°F / −15°C · BTU/h10,800–11,900182 / 182
COP at 5°F / −15°C1.98–2.26182 / 182
Equipment / loop typeHP - Split System182 / 182
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)182 / 182
Compressor stagingSingle stage182 / 182
Connected capabilityNo182 / 182

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X25M17A*+ furnace: *96MSN0601716A*AHRI reference: 21819887415.507.80114002.10EPA 4583543 →
EA*5X25M17A*+ furnace: *97CMN0801714B*AHRI reference: 21819886815.507.80115002.12EPA 4583549 →
EA*5X25M17A*+ furnace: *97CMN0601714B*AHRI reference: 21819886615.507.80115002.10EPA 4583551 →
EA*5X25M17A*+ furnace: *95CSU0601716B*AHRI reference: 21819886415.507.80113002.10EPA 4583553 →
EA*5X25M17A*+ furnace: *80CTL0901716B*AHRI reference: 21819886015.507.80114002.10EPA 4583557 →
EA*5X25M17A*+ furnace: *80CTL0701716B*AHRI reference: 21819885815.507.80114002.10EPA 4583559 →
EA*5X25M17A*+ furnace: *80CTL0451712B*AHRI reference: 21819885615.507.80115002.10EPA 4583561 →
EA*5X37M21A*+ furnace: *95MSU0401712A*AHRI reference: 21819881815.207.80118002.10EPA 4582999 →
EA*5X37M21A*+ furnace: *80CTL0451712B*AHRI reference: 21819881615.207.80117002.12EPA 4583001 →
EA*5X37M17A*+ furnace: *96VTN0601412B*AHRI reference: 21819881415.207.80115002.06EPA 4583003 →
EA*5X37M17A*+ furnace: *96MSN0601412A*AHRI reference: 21819881015.207.80116002.06EPA 4583005 →
EA*5X37M17A*+ furnace: *96MSN0261410A*AHRI reference: 21819880815.207.80115002.06EPA 4583007 →
EA*5X37M17A*+ furnace: *80CTL0451712B*AHRI reference: 21819880615.207.80114002.06EPA 4583009 →
EA*5X37M17A*+ furnace: *80MS(N,L)0451714A*AHRI reference: 21819880415.207.80114002.08EPA 4583011 →
EA*5X25M17A*+ furnace: *96VTN0601412B*AHRI reference: 21819873215.207.80115002.08EPA 4583013 →
EA*5X25M17A*+ furnace: *96VSN0601412B*AHRI reference: 21819872815.207.80115002.08EPA 4583015 →
EA*5X25M17A*+ furnace: *96MSN0601412A*AHRI reference: 21819872615.207.80116002.08EPA 4583017 →
EA*5X25M17A*+ furnace: *96MSN0261410A*AHRI reference: 21819872415.207.80116002.08EPA 4583019 →
F5MA5*30L*B*AHRI reference: 21820061615.207.80111002.06EPA 4583092 →
FMA5L30**AL*AHRI reference: 21820027815.208.10119002.16EPA 4583141 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →