B5H3V36*K*AAA*
Deluxe 23 VS Heat Pump · source records, page 8
514 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for B5H3V36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 514 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 18–22.5 | 514 / 514 |
| EER2 · BTU/Wh | 10–12.5 | 514 / 514 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 514 / 514 |
| Cooling capacity · BTU/h | 32,000–36,000 | 514 / 514 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 33,400–39,500 | 514 / 514 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–34,800 | 514 / 514 |
| Heating capacity at 5°F / −15°C · BTU/h | 25,200–29,600 | 514 / 514 |
| COP at 5°F / −15°C | 1.92–2.1 | 514 / 514 |
| Equipment / loop type | HP - Split System | 514 / 514 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 514 / 514 |
| Compressor staging | Continuously variable | 514 / 514 |
| Connected capability | No | 514 / 514 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVM5X44M21A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 218411145 | 21.50 | 8.50 | 28600 | 2.02 | EPA 4604349 → |
EVM5X44M21A*+WALLCON+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 218411137 | 21.50 | 8.50 | 29000 | 2.04 | EPA 4604357 → |
EVD5X61M21A*+WALLCON+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 218413121 | 21.50 | 8.50 | 28800 | 2.06 | EPA 4606373 → |
EVD5X61M21A*+WALLCON+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 218413113 | 21.50 | 8.50 | 28200 | 2.06 | EPA 4606381 → |
EVD5X61M21A*+WALLCON+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 218413105 | 21.50 | 8.50 | 28800 | 2.06 | EPA 4606389 → |
EVD5X61M21A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 218413097 | 21.50 | 8.50 | 28600 | 2.00 | EPA 4606397 → |
EVD5X60M24A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218413049 | 21.50 | 8.50 | 28600 | 2.06 | EPA 4606445 → |
EVD5X60M24A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218413025 | 21.50 | 8.50 | 28600 | 2.06 | EPA 4606469 → |
EVD5X60M24A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 218413001 | 21.50 | 8.50 | 28400 | 2.06 | EPA 4606493 → |
EVD5X60M24A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 218412977 | 21.50 | 8.50 | 28600 | 2.06 | EPA 4606517 → |
EVD5X60M24A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 218412945 | 21.50 | 8.50 | 28600 | 2.06 | EPA 4606549 → |
EVD5X60M21A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218412929 | 21.50 | 8.50 | 28600 | 2.04 | EPA 4606565 → |
EVD5X60M21A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218412897 | 21.50 | 8.50 | 28600 | 2.04 | EPA 4606597 → |
EVD5X60M21A*+WALLCON+ furnace: *96CTN0801714B*Cold climate designationAHRI reference: 218412889 | 21.50 | 8.50 | 28800 | 2.04 | EPA 4606605 → |
EVD5X60M21A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 218412873 | 21.50 | 8.50 | 28600 | 2.04 | EPA 4606621 → |
EVD5X60M21A*+WALLCON+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 218412865 | 21.50 | 8.50 | 29000 | 2.04 | EPA 4606629 → |
EVD5X60M21A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 218412841 | 21.50 | 8.50 | 28600 | 2.04 | EPA 4606653 → |
EVD5X60M21A*+WALLCON+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 218412833 | 21.50 | 8.50 | 29000 | 2.06 | EPA 4606661 → |
EVD5X60M21A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 218412801 | 21.50 | 8.50 | 28600 | 2.04 | EPA 4606693 → |
EVD5X60M21A*+WALLCON+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 218412793 | 21.50 | 8.50 | 28800 | 2.04 | EPA 4606701 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.