Airquest / AIR-SOURCE HEAT PUMP

B5H3V36*K*AAA*

Deluxe 23 VS Heat Pump · source records, page 4

514 published source records · source checked Sep 21, 2026

SEER2 range18–22.5BTU/Wh
HSPF2 range8.1–9.5BTU/Wh
Cooling capacity32,000–36,000BTU/h

Each efficiency range summarizes published EPA records for B5H3V36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 514 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh18–22.5514 / 514
EER2 · BTU/Wh10–12.5514 / 514
HSPF2 · BTU/Wh8.1–9.5514 / 514
Cooling capacity · BTU/h32,000–36,000514 / 514
Heating capacity at 47°F / 8.3°C · BTU/h33,400–39,500514 / 514
Heating capacity at 17°F / −8.3°C · BTU/h29,200–34,800514 / 514
Heating capacity at 5°F / −15°C · BTU/h25,200–29,600514 / 514
COP at 5°F / −15°C1.92–2.1514 / 514
Equipment / loop typeHP - Split System514 / 514
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)514 / 514
Compressor stagingContinuously variable514 / 514
Connected capabilityNo514 / 514

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVD5X60M21A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 21841290522.008.50286002.04EPA 4606589 →
EVD5X60M21A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 21841288122.008.50286002.04EPA 4606613 →
EVD5X60M21A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 21841284922.008.50284002.06EPA 4606645 →
EVD5X60M21A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 21841282522.008.50284002.04EPA 4606669 →
EVD5X60M21A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 21841281722.008.50284002.04EPA 4606677 →
EVD5X60M21A*+WALLCON+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 21841280922.008.50286002.04EPA 4606685 →
EVD5X60M21A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 21841277722.008.50286002.04EPA 4606717 →
EVD5X60M21A*+WALLCON+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 21841276922.008.50284002.04EPA 4606725 →
EVD5X49M24A*+WALLCON+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 21841276122.008.50284002.06EPA 4606733 →
EVD5X49M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 21841275322.008.50284002.06EPA 4606741 →
EVD5X49M24A*+WALLCON+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 21841273722.008.50284002.06EPA 4606757 →
EVD5X49M24A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 21841272922.008.50284002.06EPA 4606765 →
EVD5X49M24A*+WALLCON+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 21841271322.008.50284002.06EPA 4606781 →
EVD5X49M24A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 21841270522.008.50284002.06EPA 4606789 →
EVD5X49M24A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 21841268122.008.50284002.06EPA 4606813 →
EVD5X49M24A*+WALLCON+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 21841266522.008.50284002.04EPA 4606829 →
EVD5X49M24A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 21841265722.008.50284002.04EPA 4606837 →
EVD5X49M24A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 21841264922.008.50284002.04EPA 4606845 →
EVD5X42M24A*+WALLCON+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 21841248922.008.50284002.06EPA 4607005 →
EVD5X42M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 21841248122.008.50284002.06EPA 4607013 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.