SEER2 range18–23BTU/Wh
HSPF2 range8.5–10.5BTU/Wh
Cooling capacity21,600–23,800BTU/h

Each efficiency range summarizes published EPA records for B5H3V24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 419 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh18–23419 / 419
EER2 · BTU/Wh10.5–14419 / 419
HSPF2 · BTU/Wh8.5–10.5419 / 419
Cooling capacity · BTU/h21,600–23,800419 / 419
Heating capacity at 47°F / 8.3°C · BTU/h24,800–28,200419 / 419
Heating capacity at 17°F / −8.3°C · BTU/h24,000–26,400419 / 419
Heating capacity at 5°F / −15°C · BTU/h19,100–23,000419 / 419
COP at 5°F / −15°C1.84–2.1419 / 419
Equipment / loop typeHP - Split System419 / 419
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)419 / 419
Compressor stagingContinuously variable419 / 419
Connected capabilityNo419 / 419

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVM5X25M17A*+WALLCON+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 21840738521.509.00224001.98EPA 4600237
EVM5X25M17A*+WALLCON+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 21840736921.509.00224001.98EPA 4600253
EVM5X25M17A*+WALLCON+ furnace: *97CMN0601714B*Cold climate designationAHRI reference: 21840736121.509.00224001.96EPA 4600261
EVM5X25M17A*+WALLCON+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 21840735321.509.00224001.98EPA 4600269
EVM5X25M17A*+WALLCON+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 21840734521.509.00224001.98EPA 4600277
EVM5X25M17A*+WALLCON+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 21840733721.509.00224001.98EPA 4600285
EA*5X43M21A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 21840665721.5010.00192002.06EPA 4600965
EVD5X42M21A*+WALLCON+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 21840923321.509.00224001.98EPA 4602261
EVD5X42M21A*+WALLCON+ furnace: *96CTN0801714B*Cold climate designationAHRI reference: 21840921721.509.00222001.98EPA 4602277
EVD5X42M21A*+WALLCON+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 21840920921.509.00224001.98EPA 4602285
EVD5X42M21A*+WALLCON+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 21840920121.509.00224001.98EPA 4602293
EVD5X42M21A*+WALLCON+ furnace: *97CMN0601714B*Cold climate designationAHRI reference: 21840919321.509.00224001.98EPA 4602301
EVD5X42M21A*+WALLCON+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 21840918521.509.00224001.98EPA 4602309
EVD5X42M21A*+WALLCON+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 21840916921.509.00222001.98EPA 4602325
EVD5X42M21A*+WALLCON+ furnace: *80CTL0451712B*Cold climate designationAHRI reference: 21840916121.509.00224001.98EPA 4602333
EVD5X42M17A*+WALLCON+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 21840913721.509.00224001.98EPA 4602357
EVD5X42M17A*+WALLCON+ furnace: *96CTN0801714B*Cold climate designationAHRI reference: 21840912121.509.50224002.08EPA 4602373
EVD5X42M17A*+WALLCON+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 21840911321.509.00224001.98EPA 4602381
EVD5X42M17A*+WALLCON+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 21840909721.509.50224002.08EPA 4602397
EVD5X42M17A*+WALLCON+ furnace: *97CMN0601714B*Cold climate designationAHRI reference: 21840908921.509.00224001.98EPA 4602405