Heating performance & equipment details
Ranges include the 250 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18.3 | 250 / 250 |
| EER2 · BTU/Wh | 9.6–11.7 | 250 / 250 |
| HSPF2 · BTU/Wh | 8.1–9.6 | 250 / 250 |
| Cooling capacity · BTU/h | 42,500–55,500 | 250 / 250 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–56,500 | 250 / 250 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 38,000–45,000 | 250 / 250 |
| Heating capacity at 5°F / −15°C · BTU/h | 39,000–45,000 | 250 / 250 |
| COP at 5°F / −15°C | 1.75–1.95 | 250 / 250 |
| Equipment / loop type | HP - Split System | 250 / 250 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 250 / 250 |
| Compressor staging | Continuously variable | 250 / 250 |
| Connected capability | No | 250 / 250 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
7EH42CX-**+TDR+ furnace: A80UH2E110C20*Cold climate designationAHRI reference: 217188852 | 16.00 | 8.50 | 39500 | 1.80 | EPA 4007312 → |
7EH48CX-**+TDR+ furnace: A97US2V080C16X*Cold climate designationAHRI reference: 217188854 | 16.00 | 8.50 | 40000 | 1.80 | EPA 4007313 → |
7EH48CX-**+TDR+ furnace: A98USMV090C16S*Cold climate designationAHRI reference: 217188855 | 16.00 | 8.50 | 40000 | 1.80 | EPA 4007314 → |
7EH48CX-**+TDR+ furnace: A80UH1E100C20X*Cold climate designationAHRI reference: 217188856 | 16.00 | 8.50 | 40000 | 1.80 | EPA 4007315 → |
7EH48CX-**+TDR+ furnace: A98USMV090C20S*Cold climate designationAHRI reference: 217188858 | 16.00 | 8.50 | 40000 | 1.80 | EPA 4007316 → |
7EH42CX-**+TDR+ furnace: A98USMV090C16S*Cold climate designationAHRI reference: 217188800 | 16.00 | 8.50 | 40000 | 1.80 | EPA 4007385 → |
7EH48CX-**+TDR+ furnace: A97US2V090C20S*Cold climate designationAHRI reference: 217188859 | 16.00 | 8.50 | 40000 | 1.80 | EPA 4007388 → |
7E[C,U]50/60CX-**+TDR+ furnace: A80UH1E110C20*Cold climate designationAHRI reference: 217188864 | 16.00 | 8.10 | 41000 | 1.80 | EPA 4007391 → |
7EH48CX-**+TDR+ furnace: A80UH1E090C20*Cold climate designationAHRI reference: 217188817 | 16.00 | 8.50 | 39500 | 1.80 | EPA 4007405 → |
7EH48CX-**+TDR+ furnace: A80UH1E110C20*Cold climate designationAHRI reference: 217188818 | 16.00 | 8.50 | 40000 | 1.80 | EPA 4007406 → |
7EH42CX-**+TDR+ furnace: A80UH1E100C20X*Cold climate designationAHRI reference: 217188851 | 16.00 | 8.50 | 40000 | 1.80 | EPA 4008148 → |
7EH42CX-**+TDR+ furnace: A96UH1E110C20S*Cold climate designationAHRI reference: 217188853 | 16.00 | 8.50 | 39500 | 1.80 | EPA 4008149 → |
7EH60DX-**+TDR+ furnace: A80UH1E135D20*Cold climate designationAHRI reference: 217188862 | 16.00 | 8.10 | 40500 | 1.85 | EPA 4008278 → |
7E[C,U]50/60CX-**+TDR+ furnace: A80UH1E090C20*Cold climate designationAHRI reference: 217188863 | 16.00 | 8.10 | 41000 | 1.80 | EPA 4008279 → |
7EH42CX-**+TDR+ furnace: A97UH2E110C20S*Cold climate designationAHRI reference: 217450237 | 16.00 | 8.50 | 40000 | 1.80 | EPA 4045959 → |
7ED50/60CX-**+TDR+ furnace: A97DSMV090C20S*Cold climate designationAHRI reference: 217450276 | 16.00 | 8.50 | 41000 | 1.85 | EPA 4046242 → |
7ED60DX-**+TDR+ furnace: A97DSMV090C20S*Cold climate designationAHRI reference: 217450280 | 16.00 | 8.50 | 41000 | 1.90 | EPA 4046246 → |
7EH48CX-**+TDR+ furnace: A97US2V110C16S*Cold climate designationAHRI reference: 217450244 | 16.00 | 8.50 | 40000 | 1.80 | EPA 4046266 → |
7EH48CX-**+TDR+ furnace: A93UH1E110C20A*Cold climate designationAHRI reference: 217450250 | 16.00 | 8.50 | 40000 | 1.80 | EPA 4046271 → |
7E[C,U]50/60CX-**+TDR+ furnace: A80US2V090C20*Cold climate designationAHRI reference: 217450259 | 16.00 | 8.10 | 41000 | 1.80 | EPA 4046376 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →