A7SCP18V60P-**A
A7SCP18V Series
250 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for A7SCP18V60P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 250 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18.3 | 250 / 250 |
| EER2 · BTU/Wh | 9.6–11.7 | 250 / 250 |
| HSPF2 · BTU/Wh | 8.1–9.6 | 250 / 250 |
| Cooling capacity · BTU/h | 42,500–55,500 | 250 / 250 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–56,500 | 250 / 250 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 38,000–45,000 | 250 / 250 |
| Heating capacity at 5°F / −15°C · BTU/h | 39,000–45,000 | 250 / 250 |
| COP at 5°F / −15°C | 1.75–1.95 | 250 / 250 |
| Equipment / loop type | HP - Split System | 250 / 250 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 250 / 250 |
| Compressor staging | Continuously variable | 250 / 250 |
| Connected capability | No | 250 / 250 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
7E[C,U]49CX-**+TDR+ furnace: A97US2V090C16S*Cold climate designationAHRI reference: 217450219 | 18.30 | 9.00 | 39000 | 1.85 | EPA 4045948 → |
7AH1AV48PX-**Cold climate designationAHRI reference: 216013462 | 18.00 | 9.50 | 42000 | 1.75 | EPA 3801676 → |
7AH2AV42PXC-**Cold climate designationAHRI reference: 216619030 | 18.00 | 9.50 | 42500 | 1.85 | EPA 3893131 → |
7AH2AE48PX-**Cold climate designationAHRI reference: 216705389 | 18.00 | 9.50 | 43000 | 1.85 | EPA 3893248 → |
7AH1RE48DX-**Cold climate designationAHRI reference: 218636342 | 17.90 | 9.40 | 44500 | 1.80 | EPA 4661189 → |
7AH1RE42DX-**Cold climate designationAHRI reference: 218636341 | 17.90 | 9.60 | 45000 | 1.80 | EPA 4661190 → |
7E[C,U]48CX-**+TDR+ furnace: A97US2V090C16S*Cold climate designationAHRI reference: 217450209 | 17.80 | 9.00 | 39500 | 1.80 | EPA 4046171 → |
7EH42CX-**+TDR+ furnace: A97US2V090C16S*Cold climate designationAHRI reference: 217450231 | 17.80 | 9.00 | 39500 | 1.80 | EPA 4046618 → |
7E[C,U]49CX-**+TDR+ furnace: A80US2V090C20*Cold climate designationAHRI reference: 217450223 | 17.70 | 9.00 | 39000 | 1.85 | EPA 4046098 → |
7E[C,U]49CX-**+TDR+ furnace: A80US2V110C20*Cold climate designationAHRI reference: 217188786 | 17.65 | 9.00 | 39000 | 1.85 | EPA 4007137 → |
7E[C,U]49CX-**+TDR+ furnace: A80US2V110C20L*Cold climate designationAHRI reference: 217450224 | 17.65 | 9.00 | 39000 | 1.85 | EPA 4046099 → |
7AH1AE42PX-**Cold climate designationAHRI reference: 216619027 | 17.60 | 9.00 | 43000 | 1.80 | EPA 3893056 → |
7AH1AV42PX-**Cold climate designationAHRI reference: 216619028 | 17.60 | 9.00 | 43000 | 1.80 | EPA 3893057 → |
7E[C,U]49CX-**+TDR+ furnace: A93UH1E110C16A*Cold climate designationAHRI reference: 217450222 | 17.55 | 9.00 | 39000 | 1.85 | EPA 4046097 → |
7AH1AE48PX-**Cold climate designationAHRI reference: 216619029 | 17.50 | 9.00 | 43000 | 1.80 | EPA 3893130 → |
7AH2AV48PXC-**Cold climate designationAHRI reference: 216619031 | 17.50 | 9.00 | 43000 | 1.80 | EPA 3893132 → |
7AH2AE42PX-**Cold climate designationAHRI reference: 216705388 | 17.50 | 9.40 | 42500 | 1.85 | EPA 3893247 → |
7E[C,U]49CX-**+TDR+ furnace: A80US2V100C20X*Cold climate designationAHRI reference: 217188788 | 17.45 | 9.00 | 39000 | 1.85 | EPA 4007298 → |
7E[C,U]49CX-**+TDR+ furnace: A80US2V080C20X*Cold climate designationAHRI reference: 217188787 | 17.45 | 9.00 | 39000 | 1.85 | EPA 4008146 → |
7E[C,U]49CX-**+TDR+ furnace: A98USMV110C20S*Cold climate designationAHRI reference: 217188793 | 17.40 | 9.00 | 39000 | 1.85 | EPA 4007303 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →