A7SCP18V36P-**A
A7SCP18V Series · source records, page 10
216 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for A7SCP18V36P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 216 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 216 / 216 |
| EER2 · BTU/Wh | 10–12 | 216 / 216 |
| HSPF2 · BTU/Wh | 8.1–9.6 | 216 / 216 |
| Cooling capacity · BTU/h | 32,200–36,000 | 216 / 216 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 34,000–38,500 | 216 / 216 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 27,000–29,600 | 216 / 216 |
| Heating capacity at 5°F / −15°C · BTU/h | 28,000–30,800 | 216 / 216 |
| COP at 5°F / −15°C | 1.8–1.95 | 216 / 216 |
| Equipment / loop type | HP - Split System | 216 / 216 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 216 / 216 |
| Compressor staging | Continuously variable | 216 / 216 |
| Connected capability | No | 216 / 216 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
7ED30/36BX-**+TDR+ furnace: A93DF1E045B12A*Cold climate designationAHRI reference: 217450195 | 16.95 | 8.50 | 28200 | 1.85 | EPA 4046133 → |
7ED30/36BX-***+TDR+ furnace: A80DS2V090B16*Cold climate designationAHRI reference: 218114571 | 16.95 | 8.50 | 28600 | 1.85 | EPA 4573204 → |
7ED30/36BX-***+TDR+ furnace: A93DF1E045B12A*Cold climate designationAHRI reference: 218114567 | 16.95 | 8.50 | 28200 | 1.85 | EPA 4573208 → |
7ED30/36BX-***+TDR+ furnace: A96DF1E070B16S*Cold climate designationAHRI reference: 218114561 | 16.95 | 8.50 | 28800 | 1.85 | EPA 4573214 → |
7EH36BX-**+TDR+ furnace: A80UH1E090B16*Cold climate designationAHRI reference: 217188756 | 16.90 | 8.50 | 28200 | 1.85 | EPA 4006963 → |
7E[C,U]30BX-**+TDR+ furnace: A80DF1E090B16*Cold climate designationAHRI reference: 217188706 | 16.90 | 8.50 | 28400 | 1.85 | EPA 4006993 → |
7ED30/36BX-**+TDR+ furnace: A97DSMV070B12S*Cold climate designationAHRI reference: 217188762 | 16.85 | 8.50 | 28600 | 1.85 | EPA 4006969 → |
7ED30/36BX-***+TDR+ furnace: A97DSMV070B12S*Cold climate designationAHRI reference: 218114557 | 16.85 | 8.50 | 28600 | 1.85 | EPA 4573218 → |
7EH30BX-**+TDR+ furnace: A80UH2E090B16*Cold climate designationAHRI reference: 217188738 | 16.80 | 8.50 | 28200 | 1.85 | EPA 4007352 → |
7EH36BX-**+TDR+ furnace: A80UH2E090B16*Cold climate designationAHRI reference: 217188755 | 16.75 | 8.50 | 28200 | 1.85 | EPA 4006962 → |
7EH36AX-**+TDR+ furnace: A80UH2E070A12*Cold climate designationAHRI reference: 217188745 | 16.70 | 8.50 | 28800 | 1.80 | EPA 4008139 → |
7EH36AX-**+TDR+ furnace: A80US2V060A12X*Cold climate designationAHRI reference: 217188742 | 16.65 | 8.50 | 28800 | 1.80 | EPA 4006919 → |
7E[C,U]30BX-**+TDR+ furnace: A80UH1E090B16*Cold climate designationAHRI reference: 217188705 | 16.65 | 8.50 | 28400 | 1.85 | EPA 4006992 → |
7E[C,U]36CX-**+TDR+ furnace: A80UH1E110C20*Cold climate designationAHRI reference: 218082967 | 16.65 | 8.50 | 28200 | 1.90 | EPA 4569953 → |
7ED30/36BX-**+TDR+ furnace: A97DF2E045B12S*Cold climate designationAHRI reference: 217450193 | 16.60 | 8.50 | 28200 | 1.85 | EPA 4046131 → |
7ED30/36BX-***+TDR+ furnace: A97DF2E045B12S*Cold climate designationAHRI reference: 218114563 | 16.60 | 8.50 | 28200 | 1.85 | EPA 4573212 → |
7E[C,U]30BX-**+TDR+ furnace: A80UH2E090B16*Cold climate designationAHRI reference: 217188704 | 16.55 | 8.50 | 28400 | 1.85 | EPA 4006991 → |
7ED30/36BX-**+TDR+ furnace: A97DS2V070B16S*Cold climate designationAHRI reference: 216769712 | 16.50 | 8.50 | 28600 | 1.85 | EPA 3983570 → |
7ED30/36BX-***+TDR+ furnace: A97DS2V070B16S*Cold climate designationAHRI reference: 218114553 | 16.50 | 8.50 | 28600 | 1.85 | EPA 4573222 → |
7E[C,U]36BX-**+TDR+ furnace: A80UH1E080B16X*Cold climate designationAHRI reference: 217188720 | 16.40 | 8.50 | 28600 | 1.85 | EPA 4007067 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →