A7CP21V48P-**A
A7CP21V SERIES · A7CP21V Series · source records, page 3
141 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for A7CP21V48P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 141 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.7–20.5 | 141 / 141 |
| EER2 · BTU/Wh | 11–13.4 | 141 / 141 |
| HSPF2 · BTU/Wh | 7.8–9.6 | 141 / 141 |
| Cooling capacity · BTU/h | 45,000–48,000 | 141 / 141 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 42,500–51,000 | 141 / 141 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 34,200–44,000 | 141 / 141 |
| Heating capacity at 5°F / −15°C · BTU/h | 29,000–39,500 | 141 / 141 |
| COP at 5°F / −15°C | 1.88–2.2 | 141 / 141 |
| Equipment / loop type | HP - Split System | 141 / 141 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 141 / 141 |
| Compressor staging | Continuously variable | 141 / 141 |
| Connected capability | No | 141 / 141 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
7E[C,U]60CX-**+TDR+ furnace: A98USMV110C20S*Cold climate designationAHRI reference: 217120572 | 20.00 | 9.50 | 34200 | 2.10 | EPA 4006243 → |
7E[C,U]60CX-**+TDR+ furnace: A97US2V090C20S*Cold climate designationAHRI reference: 217120574 | 20.00 | 9.50 | 34400 | 2.10 | EPA 4006244 → |
7EH48CX-**+TDR+ furnace: A80US2V080C20X*Cold climate designationAHRI reference: 217120534 | 20.00 | 8.20 | 33800 | 1.98 | EPA 4006245 → |
7E[C,U]60DX-**+TDR+ furnace: A97US2V135D20S*Cold climate designationAHRI reference: 217120562 | 20.00 | 9.00 | 34000 | 2.00 | EPA 4006246 → |
7E[C,U]60CX-**+TDR+ furnace: A98USMV090C16S*Cold climate designationAHRI reference: 217120570 | 20.00 | 9.50 | 34400 | 2.10 | EPA 4006247 → |
7E[C,U]60CX-**+TDR+ furnace: A80UH1E110C20*Cold climate designationAHRI reference: 217122211 | 20.00 | 9.60 | 34400 | 2.14 | EPA 4006258 → |
7E[C,U]50/60CX-**+TDR+ furnace: A80UH2E110C16*AHRI reference: 217122187 | 20.00 | 8.20 | 29200 | 2.16 | EPA 4006362 → |
7E[C,U]60CX-**+TDR+ furnace: A93UH1E110C16A*Cold climate designationAHRI reference: 217122225 | 20.00 | 8.50 | 34000 | 2.12 | EPA 4006376 → |
7EH48CX-**+TDR+ furnace: A97US2V080C20X*Cold climate designationAHRI reference: 217120416 | 20.00 | 8.10 | 34000 | 1.96 | EPA 4011713 → |
7EH48CX-**+TDR+ furnace: A80US2V080B16X*Cold climate designationAHRI reference: 217120420 | 20.00 | 8.10 | 34200 | 1.96 | EPA 4011717 → |
7EH51CX-**+TDR+ furnace: A98USMV090C16S*Cold climate designationAHRI reference: 217446596 | 20.00 | 8.50 | 33400 | 2.04 | EPA 4044319 → |
7EH51CX-**+TDR+ furnace: A98USMV110C20S*Cold climate designationAHRI reference: 217446599 | 20.00 | 8.50 | 33200 | 2.04 | EPA 4044322 → |
7EH51CX-**+TDR+ furnace: A80US2V110C20*Cold climate designationAHRI reference: 217446592 | 20.00 | 8.50 | 33200 | 2.04 | EPA 4044323 → |
7EH51CX-**+TDR+ furnace: A80US2V080C20X*Cold climate designationAHRI reference: 217446589 | 20.00 | 8.50 | 33200 | 2.04 | EPA 4044393 → |
7EH51CX-**+TDR+ furnace: A80US2V090C20*Cold climate designationAHRI reference: 217446590 | 20.00 | 8.50 | 33200 | 2.04 | EPA 4044394 → |
7EH51CX-**+TDR+ furnace: A80US2V110C20L*Cold climate designationAHRI reference: 217446593 | 20.00 | 8.50 | 33200 | 2.04 | EPA 4044396 → |
7EH51CX-**+TDR+ furnace: A97US2V090C16S*Cold climate designationAHRI reference: 217446603 | 20.00 | 8.50 | 33400 | 2.04 | EPA 4044451 → |
7E[C,U]60CX-**+TDR+ furnace: EFV16CCA*Cold climate designationAHRI reference: 217493336 | 20.00 | 9.00 | 34200 | 2.12 | EPA 4433456 → |
7ED48CX-**+TDR+ furnace: EFV16CCA*AHRI reference: 217493340 | 20.00 | 8.00 | 32200 | 2.06 | EPA 4433460 → |
7EH51CX-**+TDR+ furnace: A97US2V110C16S*Cold climate designationAHRI reference: 217501225 | 20.00 | 8.50 | 33200 | 2.04 | EPA 4468443 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →