A7CP21V36P-**A
A7CP21V SERIES · A7CP21V Series · source records, page 2
190 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for A7CP21V36P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 190 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–20 | 190 / 190 |
| EER2 · BTU/Wh | 11–12.2 | 190 / 190 |
| HSPF2 · BTU/Wh | 8.5–10.4 | 190 / 190 |
| Cooling capacity · BTU/h | 32,000–34,800 | 190 / 190 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 30,000–34,800 | 190 / 190 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 26,600–32,400 | 190 / 190 |
| Heating capacity at 5°F / −15°C · BTU/h | 18,400–25,400 | 190 / 190 |
| COP at 5°F / −15°C | 1.84–2.46 | 190 / 190 |
| Equipment / loop type | HP - Split System | 190 / 190 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 190 / 190 |
| Compressor staging | Continuously variable | 190 / 190 |
| Connected capability | No | 190 / 190 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
7EH30BX-**+TDR+ furnace: A80UH2E090B12*Cold climate designationAHRI reference: 217446512 | 19.00 | 9.00 | 22400 | 2.46 | EPA 4044305 → |
7E[C,U]30AX-**+TDR+ furnace: A80UH1E040A12X*AHRI reference: 217446609 | 19.00 | 10.40 | 22600 | 2.26 | EPA 4044332 → |
7ED30/36CX-**+TDR+ furnace: A97DSMV090C16S*AHRI reference: 217446532 | 19.00 | 9.20 | 19500 | 2.28 | EPA 4044340 → |
7EH30BX-**+TDR+ furnace: A80US2V090B12*Cold climate designationAHRI reference: 217446537 | 19.00 | 9.40 | 22600 | 2.46 | EPA 4044345 → |
7EH30BX-**+TDR+ furnace: A80US2V090B16*Cold climate designationAHRI reference: 217446538 | 19.00 | 9.40 | 22800 | 2.46 | EPA 4044346 → |
7EH30BX-**+TDR+ furnace: A97US2V040B12X*Cold climate designationAHRI reference: 217446539 | 19.00 | 9.00 | 23200 | 2.38 | EPA 4044347 → |
7EH30BX-**+TDR+ furnace: A98USMV070B12S*Cold climate designationAHRI reference: 217446541 | 19.00 | 9.40 | 22800 | 2.44 | EPA 4044349 → |
7EH30BX-**+TDR+ furnace: A80US2V090B16L*Cold climate designationAHRI reference: 217446545 | 19.00 | 9.40 | 22800 | 2.46 | EPA 4044353 → |
7EH30BX-**+TDR+ furnace: A97US2V070B12S*Cold climate designationAHRI reference: 217446551 | 19.00 | 9.40 | 22800 | 2.42 | EPA 4044358 → |
7E[C,U]30BX-**+TDR+ furnace: A97US2V070B12S*AHRI reference: 217446500 | 19.00 | 10.40 | 23000 | 2.26 | EPA 4044448 → |
7E[C,U]36BX-**+TDR+ furnace: A80UH2E090B12*Cold climate designationAHRI reference: 217122166 | 18.50 | 9.00 | 21800 | 2.06 | EPA 4011679 → |
7E[C,U]36BX-**+TDR+ furnace: A98USMV070B12S*Cold climate designationAHRI reference: 217120404 | 18.50 | 9.00 | 22200 | 2.06 | EPA 4011702 → |
7E[C,U]36BX-**+TDR+ furnace: A97US2V070B12S*Cold climate designationAHRI reference: 217120406 | 18.50 | 9.00 | 22400 | 2.06 | EPA 4011704 → |
7E[C,U]36AX-**+TDR+ furnace: A80US2V060A12X*Cold climate designationAHRI reference: 217120408 | 18.50 | 9.00 | 22400 | 2.06 | EPA 4011705 → |
7E[C,U]36BX-**+TDR+ furnace: A80US2V080B16X*Cold climate designationAHRI reference: 217120398 | 18.50 | 9.00 | 22200 | 2.06 | EPA 4011756 → |
7E[C,U]36BX-**+TDR+ furnace: A80US2V090B12*Cold climate designationAHRI reference: 217120399 | 18.50 | 9.00 | 22200 | 2.08 | EPA 4011757 → |
7E[C,U]36BX-**+TDR+ furnace: A80US2V090B16*Cold climate designationAHRI reference: 217120400 | 18.50 | 9.00 | 22200 | 2.06 | EPA 4011758 → |
7E[C,U]36BX-**+TDR+ furnace: A80US2V090B16L*Cold climate designationAHRI reference: 217120401 | 18.50 | 9.00 | 22200 | 2.06 | EPA 4011759 → |
7E[C,U]36BX-**+TDR+ furnace: A97US2V040B12X*Cold climate designationAHRI reference: 217120402 | 18.50 | 9.00 | 22600 | 2.04 | EPA 4011760 → |
7E[C,U]36BX-**+TDR+ furnace: A97US2V060B12X*Cold climate designationAHRI reference: 217120403 | 18.50 | 8.50 | 22400 | 2.04 | EPA 4011761 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →