AIREASE / AIR-SOURCE HEAT PUMP

4SHP22LX160P-**A

4SHP22LX SERIES · 4SHP22LX Series · source records, page 2

24 published source records · source checked Sep 21, 2026

SEER2 range16–19BTU/Wh
HSPF2 range7.8–8.7BTU/Wh
Cooling capacity54,000–55,000BTU/h

Each efficiency range summarizes published EPA records for 4SHP22LX160P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 24 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16–1924 / 24
EER2 · BTU/Wh11.7–1224 / 24
HSPF2 · BTU/Wh7.8–8.724 / 24
Cooling capacity · BTU/h54,000–55,00024 / 24
Heating capacity at 47°F / 8.3°C · BTU/h55,000–56,00024 / 24
Heating capacity at 17°F / −8.3°C · BTU/h37,000–38,00024 / 24
Heating capacity at 5°F / −15°C · BTU/h29,600–31,20024 / 24
COP at 5°F / −15°C1.84–2.1224 / 24
Equipment / loop typeHP - Split System24 / 24
Refrigerant / source-reported GWPR-410A (GWP:2088)24 / 24
Compressor stagingContinuously variable24 / 24
Connected capabilityNo24 / 24

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EC60DX-0*+TDR+ furnace: A98USMV135D20AHRI reference: 21478064118.008.10308001.96EPA 3543322
7AH2AE60PX-0*AHRI reference: 21486610817.508.70296002.12EPA 3553886
EAC4X60D+TDR+ furnace: A96UH1E135D20AHRI reference: 21152901816.008.10310001.96EPA 2451754
7EC60DX-0*+TDR+ furnace: A96UH1E135D20AHRI reference: 21471663116.008.10310001.96EPA 3491348

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →