SEER2 range16–19BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,000–35,000BTU/h

Each efficiency range summarizes published EPA records for 4SHP18LX136P. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 158 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16–19158 / 158
EER2 · BTU/Wh11–12.3158 / 158
HSPF2 · BTU/Wh7.8–8.5158 / 158
Cooling capacity · BTU/h22,000–35,000158 / 158
Heating capacity at 47°F / 8.3°C · BTU/h22,000–35,000158 / 158
Heating capacity at 17°F / −8.3°C · BTU/h14,900–23,600158 / 158
Heating capacity at 5°F / −15°C · BTU/h10,900–19,600158 / 158
COP at 5°F / −15°C1.82–2.22158 / 158
Equipment / loop typeHP - Split System158 / 158
Refrigerant / source-reported GWPR-410A (GWP:2088)158 / 158
Compressor stagingContinuously variable158 / 158
Connected capabilityNo158 / 158

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EH48BX-0*+TDR+ furnace: A97UH2E045B12AHRI reference: 21472940818.008.50183002.10EPA 4010902
7EH48CX-0*+TDR+ furnace: A97UH2E090C16AHRI reference: 21472943218.008.10182002.08EPA 4010904
7EH36CX-0*+TDR+ furnace: A98USMV090C12AHRI reference: 21472938518.008.50196002.20EPA 4010917
7EH36CX-0*+TDR+ furnace: A98USMV090C16AHRI reference: 21472938618.008.50196002.22EPA 4010918
7EH36CX-0*+TDR+ furnace: A98USMV090C20AHRI reference: 21472938718.008.50196002.22EPA 4010919
7EH36CX-0*+TDR+ furnace: A98USMV110C20AHRI reference: 21472938818.008.50196002.22EPA 4010920
E*1P36C+TDR+TXV+ furnace: A98USMV090C12AHRI reference: 21253907918.008.50196002.20EPA 4010929
E*1P36C+TDR+TXV+ furnace: A98USMV090C16AHRI reference: 21253908218.008.50196002.22EPA 4010930
E*1P36C+TDR+TXV+ furnace: A98USMV090C20AHRI reference: 21253917618.008.50196002.22EPA 4010935
E*1P36C+TDR+TXV+ furnace: A98USMV110C20AHRI reference: 21253917818.008.50196002.22EPA 4010936
EA(C,U)1P30B+TDR+TXV+ furnace: A97UH2E070B12AHRI reference: 21392772118.008.10151002.06EPA 4010956
EAC4X30B+TDR+ furnace: A97UH2E070B12AHRI reference: 21392772518.008.10151002.06EPA 4010960
EAH1P30B+TDR+TXV+ furnace: A97UH2E045B12AHRI reference: 21392772618.008.50152002.11EPA 4010961
EAH1P48B+TDR+TXV+ furnace: A97UH2E045B12AHRI reference: 21392858718.008.50183002.10EPA 4010972
EAH1P48C+TDR+TXV+ furnace: A97UH2E090C16AHRI reference: 21392858918.008.10182002.08EPA 4010974
E*1P23B+TDR+TXV+ furnace: A96UH2E045B12AHRI reference: 21082190717.508.10146001.91EPA 2447268
E*1P23B+TDR+TXV+ furnace: A96UH2E070B12AHRI reference: 21082190817.508.10146001.91EPA 2447277
E*1P23B+TDR+TXV+ furnace: EFV12BCAAHRI reference: 21082191717.508.10144001.92EPA 2447278
BCE5V42M*4XAHRI reference: 21082145817.508.50182002.18EPA 2447296
ED1P30/36C+TDR+TXV+ furnace: EFV16CCAAHRI reference: 21082186217.508.10176002.08EPA 2447302

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →