Heating performance & equipment details
Ranges include the 226 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–15.8 | 226 / 226 |
| EER2 · BTU/Wh | 12.5–13 | 226 / 226 |
| HSPF2 · BTU/Wh | 8–8.5 | 226 / 226 |
| Cooling capacity · BTU/h | 46,000–48,000 | 226 / 226 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 44,500–47,000 | 226 / 226 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 30,000–31,800 | 226 / 226 |
| Heating capacity at 5°F / −15°C · BTU/h | 24,200–26,000 | 226 / 226 |
| COP at 5°F / −15°C | 2.16–2.38 | 226 / 226 |
| Equipment / loop type | HP - Split System | 226 / 226 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 226 / 226 |
| Compressor staging | Single stage | 226 / 226 |
| Connected capability | No | 226 / 226 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
7EC60CX-0*+TDR+ furnace: A80UH2E110C16AHRI reference: 214716108 | 15.60 | 8.30 | 25200 | 2.36 | EPA 3489781 → |
7EC60CX-0*+TDR+ furnace: A80UH2E110C20AHRI reference: 214716109 | 15.60 | 8.30 | 25200 | 2.38 | EPA 3489784 → |
7EC49CX-0*+TDR+ furnace: A80UH1E090C20AHRI reference: 214716062 | 15.60 | 8.10 | 25000 | 2.26 | EPA 3489815 → |
7EC60CX-0*+TDR+ furnace: A80US2V100C20XAHRI reference: 214716126 | 15.60 | 8.30 | 25400 | 2.38 | EPA 3489895 → |
7EC48CX-0*+TDR+ furnace: A80UH2E110C20AHRI reference: 214716026 | 15.60 | 8.10 | 24200 | 2.20 | EPA 3489901 → |
7EH51CX-0*+TDR+ furnace: A80UH1E090C20AHRI reference: 214715984 | 15.60 | 8.30 | 25200 | 2.30 | EPA 3489935 → |
7EC60CX-0*+TDR+ furnace: A80UH1E090C20AHRI reference: 214716117 | 15.60 | 8.10 | 25200 | 2.38 | EPA 3489939 → |
7EH51CX-0*+TDR+ furnace: A80US2V080C20XAHRI reference: 214715990 | 15.60 | 8.30 | 25400 | 2.32 | EPA 3489952 → |
7EC49CX-0*+TDR+ furnace: A80US2V080C20XAHRI reference: 214716069 | 15.60 | 8.10 | 25400 | 2.28 | EPA 3489962 → |
EA(C;U)1P60C+TDR+TXV+ furnace: A80US2V110C20AHRI reference: 210329751 | 15.40 | 8.30 | 25400 | 2.32 | EPA 2456372 → |
EA(C;U)1P60C+TDR+TXV+ furnace: A93UH1E110C20AHRI reference: 210329741 | 15.40 | 8.30 | 25400 | 2.32 | EPA 2456508 → |
EAC4X48C+TDR+ furnace: A80UH1E090C20AHRI reference: 211663220 | 15.40 | 8.10 | 24400 | 2.22 | EPA 2456763 → |
EAC4X48C+TDR+ furnace: A93UH1E110C20AHRI reference: 211663222 | 15.40 | 8.10 | 24400 | 2.18 | EPA 2456764 → |
EAC4X60C+TDR+ furnace: A80US2V110C20AHRI reference: 211663263 | 15.40 | 8.30 | 25400 | 2.32 | EPA 2456770 → |
EAC4X60C+TDR+ furnace: A80US2V110C20LAHRI reference: 211663264 | 15.40 | 8.30 | 25400 | 2.32 | EPA 2456771 → |
EAC4X48C+TDR+ furnace: A80US2V080C20XAHRI reference: 211663224 | 15.40 | 8.10 | 24400 | 2.24 | EPA 2456791 → |
EAC4X49C+TDR+ furnace: A80UH2E110C16AHRI reference: 211663227 | 15.40 | 8.10 | 25400 | 2.26 | EPA 2456792 → |
EAC4X49C+TDR+ furnace: A80UH2E110C20AHRI reference: 211663228 | 15.40 | 8.10 | 25400 | 2.26 | EPA 2456796 → |
EAC4X48C+TDR+ furnace: A80US2V100C20XAHRI reference: 211663225 | 15.40 | 8.10 | 24400 | 2.20 | EPA 2456797 → |
EAC4X60C+TDR+ furnace: A80UH1E110C20AHRI reference: 211663254 | 15.40 | 8.30 | 25400 | 2.34 | EPA 2456806 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →