AIREASE / AIR-SOURCE HEAT PUMP

4SHP17LE136P-**A

4HSP17LE Series · 4SHP17 SERIES · 4SHP17L SERIES · 4SHP17LE SERIES · 4SHP17LE Series · 4SHP17LE1 Series · source records, page 6

454 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.7BTU/Wh
Cooling capacity34,800–36,000BTU/h

Each efficiency range summarizes published EPA records for 4SHP17LE136P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 454 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8454 / 454
EER2 · BTU/Wh12.2–14454 / 454
HSPF2 · BTU/Wh7.8–8.7454 / 454
Cooling capacity · BTU/h34,800–36,000454 / 454
Heating capacity at 47°F / 8.3°C · BTU/h32,400–36,000454 / 454
Heating capacity at 17°F / −8.3°C · BTU/h21,400–24,000454 / 454
Heating capacity at 5°F / −15°C · BTU/h16,800–19,300454 / 454
COP at 5°F / −15°C2.06–2.36454 / 454
Equipment / loop typeHP - Split System454 / 454
Refrigerant / source-reported GWPR-410A (GWP:2088)454 / 454
Compressor stagingSingle stage454 / 454
Connected capabilityNo454 / 454

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EAC4X50/60C+TDR+ furnace: A93UH1E110C16AHRI reference: 21166316916.207.80170002.12EPA 2456709 →
EA(C;U)1P50/60C+TDR+TXV+ furnace: A96UH1E090C16AHRI reference: 21032986216.207.80172002.12EPA 2456726 →
EAC4X50/60C+TDR+ furnace: A80US2V100C20XAHRI reference: 21166317516.208.10174002.14EPA 2456820 →
EA(C;U)1P50/60C+TDR+TXV+ furnace: A80US2V100C20XAHRI reference: 21032986816.208.10174002.14EPA 2457543 →
EA(C;U)1P50/60C+TDR+TXV+ furnace: A93UH1E090C16AHRI reference: 21032986016.207.80172002.14EPA 2457546 →
EA(C;U)1P36B+TDR+TXV+ furnace: A80US2V090B16AHRI reference: 21166311316.207.80172002.14EPA 2458055 →
EAC4X50/60C+TDR+ furnace: A96UH1E110C20AHRI reference: 21166317216.207.80172002.12EPA 2458069 →
EA(C;U)1P36A+TDR+TXV+ furnace: A80UH1E070B12AHRI reference: 21032984116.207.80172002.14EPA 2459168 →
EA(C;U)1P36B+TDR+TXV+ furnace: A80UH1E070B12AHRI reference: 21166310416.207.80172002.14EPA 2459211 →
EAC4X36B+TDR+ furnace: A80US2V090B16AHRI reference: 21166315116.207.80172002.14EPA 2459225 →
EAC4X36B+TDR+ furnace: A80UH1E070B12AHRI reference: 21166314216.207.80172002.14EPA 2459481 →
EAC4X50/60C+TDR+ furnace: A80UH1E110C20AHRI reference: 21166316616.207.80173002.12EPA 2459483 →
EAH1P51C*+TDR+TXV+ furnace: A97USMV110C20AHRI reference: 21173686316.208.10176002.18EPA 2462827 →
EAH1P48B*+TDR+TXV+ furnace: A80UH2E090B16AHRI reference: 21173632616.208.00172002.20EPA 2463252 →
EAH1P51C*+TDR+TXV+ furnace: A97US2V080C16XAHRI reference: 21173684316.208.00177002.20EPA 2463266 →
EAH1P51C*+TDR+TXV+ furnace: A97USMV090C12AHRI reference: 21173685016.208.00176002.18EPA 2463267 →
EAH1P51C*+TDR+TXV+ furnace: A97USMV090C16AHRI reference: 21173685416.208.00174002.16EPA 2463270 →
EAH1P51C*+TDR+TXV+ furnace: A93UH1E090C16AHRI reference: 21173674216.207.80173002.16EPA 2464495 →
EAH1P51C*+TDR+TXV+ furnace: A93UH1E090C12AHRI reference: 21173672716.207.80175002.16EPA 2464905 →
EAH1P51C*+TDR+TXV+ furnace: A96UH1E090C16AHRI reference: 21173679016.208.00175002.18EPA 2465753 →