AIREASE / AIR-SOURCE HEAT PUMP

4SHP17LE136P-**A

4HSP17LE Series · 4SHP17 SERIES · 4SHP17L SERIES · 4SHP17LE SERIES · 4SHP17LE Series · 4SHP17LE1 Series · source records, page 18

454 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.7BTU/Wh
Cooling capacity34,800–36,000BTU/h

Each efficiency range summarizes published EPA records for 4SHP17LE136P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 454 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8454 / 454
EER2 · BTU/Wh12.2–14454 / 454
HSPF2 · BTU/Wh7.8–8.7454 / 454
Cooling capacity · BTU/h34,800–36,000454 / 454
Heating capacity at 47°F / 8.3°C · BTU/h32,400–36,000454 / 454
Heating capacity at 17°F / −8.3°C · BTU/h21,400–24,000454 / 454
Heating capacity at 5°F / −15°C · BTU/h16,800–19,300454 / 454
COP at 5°F / −15°C2.06–2.36454 / 454
Equipment / loop typeHP - Split System454 / 454
Refrigerant / source-reported GWPR-410A (GWP:2088)454 / 454
Compressor stagingSingle stage454 / 454
Connected capabilityNo454 / 454

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EAD4X-48C+TDR+ furnace: A97DSMV090C16AHRI reference: 21326498615.808.60193002.30EPA 2839786
EAD4X-30/36C+TDR+ furnace: A93DF1E090C16AHRI reference: 21326497015.808.00187002.14EPA 2840012
EAD4X-48C+TDR+ furnace: A97DSMV090C20AHRI reference: 21326498715.808.60190002.26EPA 2840025
EA(C;U)1P36B+TDR+TXV+ furnace: A98USMV070B12AHRI reference: 21380520615.807.80174002.12EPA 2856906
EAC4X36B+TDR+ furnace: A98USMV070B12AHRI reference: 21380520715.807.80174002.12EPA 2856907
EA(C;U)1P50/60C+TDR+TXV+ furnace: A98USMV090C20AHRI reference: 21380503415.807.80176002.12EPA 2856916
EAC4X50/60C+TDR+ furnace: A98USMV090C20AHRI reference: 21380521015.807.80176002.12EPA 2857951
EA(C;U)1P36A+TDR+TXV+ furnace: A98USMV070B12AHRI reference: 21380503315.807.80174002.12EPA 2858021
EA(C;U)1P50/60C+TDR+TXV+ furnace: A97US2V090C20SAHRI reference: 21407480915.807.80176002.12EPA 3391943
EAC4X36B+TDR+ furnace: A97US2V070B12SAHRI reference: 21407482015.807.80174002.12EPA 3392004
EAC4X50/60C+TDR+ furnace: A97US2V090C20SAHRI reference: 21407482315.807.80176002.12EPA 3392006
EA(C;U)1P36B+TDR+TXV+ furnace: A97US2V070B12SAHRI reference: 21407480615.807.80174002.12EPA 3392083
7ED30/36BX-0*+TDR+ furnace: A80DF1E090B16AHRI reference: 21471563615.808.00187002.14EPA 3489336
7EH42BX-0*+TDR+ furnace: A80UH1E080B16XAHRI reference: 21471553215.808.00183002.20EPA 3489341
7ED48CX-0*+TDR+ furnace: A97DS2V090C20S*AHRI reference: 21471565715.808.60190002.24EPA 3489407
7ED48CX-0*+TDR+ furnace: A97DS2V110C20S*AHRI reference: 21471565915.808.60190002.26EPA 3489413
7EH42BX-0*+TDR+ furnace: A93UH1E045B12AHRI reference: 21471554215.808.00186002.24EPA 3489510
7EH42BX-0*+TDR+ furnace: A96UH1E030B12AHRI reference: 21471554415.808.00185002.24EPA 3489515
7EH42BX-0*+TDR+ furnace: A96UH1E070B12AHRI reference: 21471554515.808.00186002.24EPA 3489520
7EC50/60CX-0*+TDR+ furnace: A80UH1E100C20XAHRI reference: 21471573015.807.80176002.12EPA 3489539

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.