AIREASE / AIR-SOURCE HEAT PUMP

4SHP17LE136P-**A

4HSP17LE Series · 4SHP17 SERIES · 4SHP17L SERIES · 4SHP17LE SERIES · 4SHP17LE Series · 4SHP17LE1 Series · source records, page 12

454 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.7BTU/Wh
Cooling capacity34,800–36,000BTU/h

Each efficiency range summarizes published EPA records for 4SHP17LE136P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 454 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8454 / 454
EER2 · BTU/Wh12.2–14454 / 454
HSPF2 · BTU/Wh7.8–8.7454 / 454
Cooling capacity · BTU/h34,800–36,000454 / 454
Heating capacity at 47°F / 8.3°C · BTU/h32,400–36,000454 / 454
Heating capacity at 17°F / −8.3°C · BTU/h21,400–24,000454 / 454
Heating capacity at 5°F / −15°C · BTU/h16,800–19,300454 / 454
COP at 5°F / −15°C2.06–2.36454 / 454
Equipment / loop typeHP - Split System454 / 454
Refrigerant / source-reported GWPR-410A (GWP:2088)454 / 454
Compressor stagingSingle stage454 / 454
Connected capabilityNo454 / 454

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EAH1P51C*+TDR+TXV+ furnace: A97USMV090C20AHRI reference: 21173685816.008.10178002.16EPA 2462826
EAH1P51C*+TDR+TXV+ furnace: A97US2V080C20XAHRI reference: 21173684716.008.10178002.18EPA 2463269
EAH1P48B*+TDR+TXV+ furnace: A80UH1E070B12AHRI reference: 21173640616.008.00173002.18EPA 2464477
EAH1P48B*+TDR+TXV+ furnace: A93UH1E070B12AHRI reference: 21173646716.007.80172002.20EPA 2464494
EAH1P51C*+TDR+TXV+ furnace: A80UH1E100C20XAHRI reference: 21173654516.008.00176002.18EPA 2466630
EAH1P51C*+TDR+TXV+ furnace: A80US2V090C20AHRI reference: 21173681616.008.10178002.18EPA 2468431
EAH1P51C*+TDR+TXV+ furnace: A80US2V110C20AHRI reference: 21173683516.008.00179002.20EPA 2469316
EAH1P51C*+TDR+TXV+ furnace: A80US2V110C20LAHRI reference: 21173683916.008.00179002.20EPA 2469321
EAD4X-30/36C+TDR+ furnace: A96DF1E090C16AHRI reference: 21326497116.008.00187002.16EPA 2840013
EAD4X-30/36C+TDR+ furnace: A80DS2V110C20AHRI reference: 21326497316.008.10187002.18EPA 2840014
EAH1P51C*+TDR+TXV+ furnace: A98USMV090C20AHRI reference: 21380530116.008.10178002.16EPA 2856816
EAC4X50/60C+TDR+ furnace: A98USMV090C12AHRI reference: 21380520816.007.80173002.12EPA 2856908
EAC4X50/60C+TDR+ furnace: A98USMV090C16AHRI reference: 21380520916.007.80174002.12EPA 2856909
EA(C;U)1P50/60C+TDR+TXV+ furnace: A98USMV110C20AHRI reference: 21380503516.007.80174002.12EPA 2856917
EA(C;U)1P50/60C+TDR+TXV+ furnace: A98USMV090C16AHRI reference: 21380503616.007.80174002.12EPA 2856918
EA(C;U)1P50/60C+TDR+TXV+ furnace: A98USMV090C12AHRI reference: 21380503716.007.80173002.12EPA 2856920
EAC4X50/60C+TDR+ furnace: A98USMV110C20AHRI reference: 21380521116.007.80174002.12EPA 2857954
EA(C;U)1P50/60C+TDR+TXV+ furnace: A97US2V090C16SAHRI reference: 21407480816.007.80174002.12EPA 3391942
EA(C;U)1P50/60C+TDR+TXV+ furnace: A97US2V110C16SAHRI reference: 21407481016.007.80173002.12EPA 3391944
EA(C;U)1P50/60C+TDR+TXV+ furnace: A97US2V110C20SAHRI reference: 21407481116.007.80174002.12EPA 3391945

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →