AIREASE / AIR-SOURCE HEAT PUMP

4SHP17LE130P-**A

4HSP17LE Series · 4SHP17 SERIES · 4SHP17L SERIES · 4SHP17LE SERIES · 4SHP17LE Series · 4SHP17LE1 Series · source records, page 9

333 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,600BTU/h

Each efficiency range summarizes published EPA records for 4SHP17LE130P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 333 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.2333 / 333
EER2 · BTU/Wh12.2–13.5333 / 333
HSPF2 · BTU/Wh7.8–8.6333 / 333
Cooling capacity · BTU/h28,200–30,600333 / 333
Heating capacity at 47°F / 8.3°C · BTU/h26,600–30,000333 / 333
Heating capacity at 17°F / −8.3°C · BTU/h17,200–19,600333 / 333
Heating capacity at 5°F / −15°C · BTU/h13,200–15,400333 / 333
COP at 5°F / −15°C1.96–2.38333 / 333
Equipment / loop typeHP - Split System333 / 333
Refrigerant / source-reported GWPR-410A (GWP:2088)333 / 333
Compressor stagingSingle stage333 / 333
Connected capabilityNo333 / 333

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7ED42BX-0*+TDR+ furnace: A80DF1E070B12AHRI reference: 21471546115.808.60153002.34EPA 3491682
7EH30BX-0*+TDR+ furnace: A97US2V040B12XAHRI reference: 21471542415.808.00137002.08EPA 3491827
7EC36AX-0*+TDR+ furnace: A80US2V070A12AHRI reference: 21471550715.808.10144002.26EPA 3491829
7EH30BX-0*+TDR+ furnace: A98USMV070B12AHRI reference: 21478052615.808.00137002.08EPA 3543172
7AH1AE30PX-0*AHRI reference: 21486607115.807.80137002.14EPA 3553686
7AH2AE30PX-0*AHRI reference: 21486599115.808.50147002.36EPA 3553825
7AH1AV36PX-0*AHRI reference: 21486601715.808.10134002.16EPA 3553898
EA(C;U)1P30A+TDR+TXV+ furnace: A93UH1E045B12AHRI reference: 21032997315.608.00144002.20EPA 2456334
EA(C;U)1P36A+TDR+TXV+ furnace: A80UH1E080B16XAHRI reference: 21033000215.608.10146002.24EPA 2456366
EA(C;U)1P30A+TDR+TXV+ furnace: A97US2V060B12XAHRI reference: 21032998815.608.00145002.20EPA 2456382
EA(C;U)1P30A+TDR+TXV+ furnace: A97US2V040B12XAHRI reference: 21032998715.608.00145002.20EPA 2456428
EA(C;U)1P36A+TDR+TXV+ furnace: A96UH1E070B12AHRI reference: 21033000615.608.10143002.26EPA 2456725
EA(C;U)1P36B+TDR+TXV+ furnace: A96UH1E045B12AHRI reference: 21166301215.608.10146002.26EPA 2456837
EA(C;U)1P36B+TDR+TXV+ furnace: A96UH1E030B12AHRI reference: 21166301115.608.00143002.24EPA 2456840
EA(C;U)1P36B+TDR+TXV+ furnace: A96UH1E070B12AHRI reference: 21166301315.608.10143002.26EPA 2456843
EAC4X30A+TDR+ furnace: A80UH2E070A12AHRI reference: 21166304015.608.00144002.20EPA 2456847
EAC4X30A+TDR+ furnace: A80UH1E070A12AHRI reference: 21166304215.608.00144002.20EPA 2456851
EAC4X30A+TDR+ furnace: A80US2V070A12LAHRI reference: 21166304515.608.00145002.20EPA 2456855
EAC4X30A+TDR+ furnace: A80US2V070A12AHRI reference: 21166304415.608.00145002.20EPA 2456856
EAC4X36B+TDR+ furnace: A80UH1E080B16XAHRI reference: 21166307615.608.10146002.24EPA 2456866

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →