AIREASE / AIR-SOURCE HEAT PUMP

4SHP17LE124P-**A

4HSP17LE Series · 4SHP17 SERIES · 4SHP17L SERIES · 4SHP17LE SERIES · 4SHP17LE Series · 4SHP17LE1 Series · source records, page 7

317 published source records · source checked Sep 21, 2026

SEER2 range15.4–17BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity22,400–24,000BTU/h

Each efficiency range summarizes published EPA records for 4SHP17LE124P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 317 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.4–17317 / 317
EER2 · BTU/Wh12.5–14317 / 317
HSPF2 · BTU/Wh7.8–8.2317 / 317
Cooling capacity · BTU/h22,400–24,000317 / 317
Heating capacity at 47°F / 8.3°C · BTU/h21,000–22,600317 / 317
Heating capacity at 17°F / −8.3°C · BTU/h13,400–14,700317 / 317
Heating capacity at 5°F / −15°C · BTU/h10,200–11,500317 / 317
COP at 5°F / −15°C2–2.16317 / 317
Equipment / loop typeHP - Split System317 / 317
Refrigerant / source-reported GWPR-410A (GWP:2088)317 / 317
Compressor stagingSingle stage317 / 317
Connected capabilityNo317 / 317

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EH24AX-0*+TDR+ furnace: A80US2V060A12XAHRI reference: 21471528016.407.80104002.10EPA 3489502
7ED30/36CX-0*+TDR+ furnace: A96DF1E090C16AHRI reference: 21471533016.408.20112002.10EPA 3489512
7EC24BX-0*+TDR+ furnace: A80UH2E090B16AHRI reference: 21471534516.407.80104002.04EPA 3489518
7EC30BX-0*+TDR+ furnace: A97US2V070B12S*AHRI reference: 21471538116.407.80104002.06EPA 3489546
7EH24AX-0*+TDR+ furnace: A80UH2E045A12AHRI reference: 21471527616.407.80102002.04EPA 3489559
7EC30AX-0*+TDR+ furnace: A80UH2E045A12AHRI reference: 21471536716.407.80102002.06EPA 3489561
7EC30AX-0*+TDR+ furnace: A80US2V070A12AHRI reference: 21471537216.407.80104002.04EPA 3489567
7EH24AX-0*+TDR+ furnace: A80UH1E070A12AHRI reference: 21471527916.407.80104002.06EPA 3491597
7EC30BX-0*+TDR+ furnace: A80UH1E070B12AHRI reference: 21471538216.407.80104002.06EPA 3491853
7EC24BX-0*+TDR+ furnace: A97US2V070B12S*AHRI reference: 21471534916.407.80104002.04EPA 3491894
7EH30BX-0*+TDR+ furnace: A96UH1E030B12AHRI reference: 21471530616.407.80102002.02EPA 3491895
7EC24BX-0*+TDR+ furnace: A98USMV070B12AHRI reference: 21478052416.407.80104002.04EPA 3543170
7EC30BX-0*+TDR+ furnace: A98USMV070B12AHRI reference: 21478052516.407.80104002.06EPA 3543171
EAC4X30B+TDR+ furnace: A97USMV070B12AHRI reference: 21166297716.407.80104002.06EPA 3990416
EAC4X24A+TDR+ furnace: A80US2V070A12AHRI reference: 21166292516.207.80104002.04EPA 2471049
EA(C;U)1P30B+TDR+TXV+ furnace: A97US2V060B12XAHRI reference: 21166290516.207.80104002.02EPA 2471064
EA(C;U)1P30B+TDR+TXV+ furnace: A93UH1E030B12AHRI reference: 21166289516.207.80102002.00EPA 2471071
EA(C;U)1P30B+TDR+TXV+ furnace: A97US2V040B12XAHRI reference: 21166290416.207.80104002.08EPA 2471078
EA(C;U)1P24B+TDR+TXV+ furnace: A97US2V040B12XAHRI reference: 21166288316.207.80104002.04EPA 2471085
EA(C;U)1P24B+TDR+TXV+ furnace: A97US2V060B12XAHRI reference: 21166288416.207.80104002.02EPA 2471089

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →