SEER2 range15.4–17BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity22,400–24,000BTU/h

Each efficiency range summarizes published EPA records for 4SHP17LE124P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 317 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.4–17317 / 317
EER2 · BTU/Wh12.5–14317 / 317
HSPF2 · BTU/Wh7.8–8.2317 / 317
Cooling capacity · BTU/h22,400–24,000317 / 317
Heating capacity at 47°F / 8.3°C · BTU/h21,000–22,600317 / 317
Heating capacity at 17°F / −8.3°C · BTU/h13,400–14,700317 / 317
Heating capacity at 5°F / −15°C · BTU/h10,200–11,500317 / 317
COP at 5°F / −15°C2–2.16317 / 317
Equipment / loop typeHP - Split System317 / 317
Refrigerant / source-reported GWPR-410A (GWP:2088)317 / 317
Compressor stagingSingle stage317 / 317
Connected capabilityNo317 / 317

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EAC4X30B+TDR+ furnace: A80US2V090B12AHRI reference: 21166297316.608.00104002.08EPA 3990415
EAC4X24B+TDR+ furnace: A80UH1E070B12AHRI reference: 21166293416.407.80104002.04EPA 2471044
EAC4X24A+TDR+ furnace: A80US2V060A12XAHRI reference: 21166292416.407.80104002.08EPA 2471047
EAC4X24B+TDR+ furnace: A80UH2E090B16AHRI reference: 21166292916.407.80104002.04EPA 2471059
EA(C;U)1P24B+TDR+TXV+ furnace: A80UH1E090B16AHRI reference: 21166287316.407.80104002.08EPA 2471061
EA(C;U)1P30B+TDR+TXV+ furnace: A97USMV070B12AHRI reference: 21166290616.407.80104002.06EPA 2471066
EA(C;U)1P30B+TDR+TXV+ furnace: A80US2V080B16XAHRI reference: 21166290116.407.80104002.06EPA 2471070
EA(C;U)1P30B+TDR+TXV+ furnace: A80UH2E090B16AHRI reference: 21166288816.408.00104002.06EPA 2471075
EA(C;U)1P30B+TDR+TXV+ furnace: A80UH1E070B12AHRI reference: 21166289316.407.80104002.06EPA 2471088
EA(C;U)1P24B+TDR+TXV+ furnace: A80UH2E090B16AHRI reference: 21166286716.407.80104002.04EPA 2471093
EA(C;U)1P24B+TDR+TXV+ furnace: A97USMV070B12AHRI reference: 21166288516.407.80104002.04EPA 2471094
EAH1P30A*+TDR+TXV+ furnace: A80US2V070A12AHRI reference: 21173511116.408.10106002.12EPA 2471273
EAH1P30A*+TDR+TXV+ furnace: A80US2V070A12LAHRI reference: 21173511316.408.10106002.12EPA 2471279
EAH1P30B*+TDR+TXV+ furnace: A80UH1E080B16XAHRI reference: 21173512216.407.80106002.02EPA 2471289
EAH1P30A*+TDR+TXV+ furnace: A80UH1E070A12AHRI reference: 21173509416.408.00104002.14EPA 2471295
EAC4X30A+TDR+ furnace: A80US2V070A12AHRI reference: 21166295516.407.80104002.04EPA 2471302
EAC4X24B+TDR+ furnace: A97USMV070B12AHRI reference: 21166294716.407.80104002.04EPA 2471316
EAH1P30A*+TDR+TXV+ furnace: A80UH1E045A12AHRI reference: 21173507816.408.00102002.08EPA 2471346
EAH1P24A*+TDR+TXV+ furnace: A80UH1E070A12AHRI reference: 21173498516.407.80104002.06EPA 2471822
EAH1P24A*+TDR+TXV+ furnace: A80US2V060A12XAHRI reference: 21173499916.407.80104002.10EPA 2471832

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.