AIREASE / AIR-SOURCE HEAT PUMP

4SHP17LE124P-**A

4HSP17LE Series · 4SHP17 SERIES · 4SHP17L SERIES · 4SHP17LE SERIES · 4SHP17LE Series · 4SHP17LE1 Series · source records, page 13

317 published source records · source checked Sep 21, 2026

SEER2 range15.4–17BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity22,400–24,000BTU/h

Each efficiency range summarizes published EPA records for 4SHP17LE124P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 317 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.4–17317 / 317
EER2 · BTU/Wh12.5–14317 / 317
HSPF2 · BTU/Wh7.8–8.2317 / 317
Cooling capacity · BTU/h22,400–24,000317 / 317
Heating capacity at 47°F / 8.3°C · BTU/h21,000–22,600317 / 317
Heating capacity at 17°F / −8.3°C · BTU/h13,400–14,700317 / 317
Heating capacity at 5°F / −15°C · BTU/h10,200–11,500317 / 317
COP at 5°F / −15°C2–2.16317 / 317
Equipment / loop typeHP - Split System317 / 317
Refrigerant / source-reported GWPR-410A (GWP:2088)317 / 317
Compressor stagingSingle stage317 / 317
Connected capabilityNo317 / 317

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EC30BX-0*+TDR+ furnace: A80UH2E090B12AHRI reference: 21471537616.007.80106002.00EPA 3489430
7EC24BX-0*+TDR+ furnace: A80US2V090B16AHRI reference: 21471536016.007.80104002.04EPA 3489470
7EC30BX-0*+TDR+ furnace: A80US2V090B16AHRI reference: 21471539216.007.80104002.00EPA 3489493
7EH30AX-0*+TDR+ furnace: A80UH1E040A12XAHRI reference: 21471528416.008.10105002.10EPA 3489506
7ED30/36BX-0*+TDR+ furnace: A97DSMV070B12AHRI reference: 21471532516.008.10111002.08EPA 3489507
7ED30/36CX-0*+TDR+ furnace: A97DF2E090C16AHRI reference: 21471532616.008.20113002.10EPA 3489508
7EC24BX-0*+TDR+ furnace: A80UH2E090B12AHRI reference: 21471534416.007.80106002.02EPA 3489517
7EC24BX-0*+TDR+ furnace: A97US2V045B12S*AHRI reference: 21471534716.007.80104002.02EPA 3489521
7ED30/36BX-0*+TDR+ furnace: A80DF1E070B12AHRI reference: 21471531916.008.10112002.10EPA 3489528
7EC30BX-0*+TDR+ furnace: A96UH1E030B12AHRI reference: 21471538716.007.80102002.00EPA 3489552
7EC30AX-0*+TDR+ furnace: A80UH1E040A12XAHRI reference: 21471536516.007.80106002.04EPA 3489560
7EC30AX-0*+TDR+ furnace: A80UH1E060A12XAHRI reference: 21471536616.007.80106002.04EPA 3491849
7AH1AE24PX-0*AHRI reference: 21486607916.007.80104002.08EPA 3553689
7AH1AE30PX-0*AHRI reference: 21486608116.008.10108002.06EPA 3553690
7AH2AE30PX-0*AHRI reference: 21486606216.008.20108002.16EPA 3553817
7AH1AV30PX-0*AHRI reference: 21486606016.008.10104002.06EPA 3553818
EAC4X24B+TDR+ furnace: A93UH1E045B12AHRI reference: 21166293715.807.80106002.00EPA 2471046
EA(C;U)1P30B+TDR+TXV+ furnace: A80UH1E080B16XAHRI reference: 21166288615.807.80106002.04EPA 2471077
EA(C;U)1P30B+TDR+TXV+ furnace: A93UH1E045B12AHRI reference: 21166289615.807.80106002.00EPA 2471087
EA(C;U)1P24B+TDR+TXV+ furnace: A80UH1E080B16XAHRI reference: 21166286515.807.80106002.02EPA 2471097

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →