SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity18,000BTU/h

Each efficiency range summarizes published EPA records for 4SHP17LE118P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 331 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8331 / 331
EER2 · BTU/Wh12.2–14331 / 331
HSPF2 · BTU/Wh7.8–8.5331 / 331
Cooling capacity · BTU/h18,000331 / 331
Heating capacity at 47°F / 8.3°C · BTU/h16,000–18,000331 / 331
Heating capacity at 17°F / −8.3°C · BTU/h10,200–12,100331 / 331
Heating capacity at 5°F / −15°C · BTU/h7,500–9,700331 / 331
COP at 5°F / −15°C1.9–2.16331 / 331
Equipment / loop typeHP - Split System331 / 331
Refrigerant / source-reported GWPR-410A (GWP:2088)331 / 331
Compressor stagingSingle stage331 / 331
Connected capabilityNo331 / 331

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EAC4X30B+TDR+ furnace: A80US2V090B16AHRI reference: 21166286116.408.0080001.96EPA 2458664
EAC4X24A+TDR+ furnace: A80UH1E070A12AHRI reference: 21166281416.408.0082002.10EPA 2458969
EAC4X24A+TDR+ furnace: A80UH2E070A12AHRI reference: 21166281216.408.1082002.12EPA 2458971
EA(C;U)1P24A+TDR+TXV+ furnace: A97USMV070B12AHRI reference: 21033020916.408.1084002.08EPA 2459164
EAC4X24B+TDR+ furnace: A80US2V090B12AHRI reference: 21166283116.408.1086002.10EPA 2459216
EAC4X24B+TDR+ furnace: A97US2V060B12XAHRI reference: 21166283416.408.1084002.06EPA 2459238
EA(C;U)1P24A+TDR+TXV+ furnace: A80UH2E090B12AHRI reference: 21033020116.408.1081002.12EPA 2459339
EA(C;U)1P24A+TDR+TXV+ furnace: A80UH1E070A12AHRI reference: 21033018616.408.0082002.10EPA 2459393
EA(C;U)1P24B+TDR+TXV+ furnace: A80UH2E090B12AHRI reference: 21166275016.408.1081002.12EPA 2459467
EAC4X24B+TDR+ furnace: A97USMV070B12AHRI reference: 21166283516.408.1084002.08EPA 2459492
EAC4X24B+TDR+ furnace: A97US2V040B12XAHRI reference: 21166283316.408.1084002.06EPA 2459504
EA(C;U)1P24A+TDR+TXV+ furnace: A97US2V060B12XAHRI reference: 21033020816.408.1084002.06EPA 2459663
EAH1P24A*+TDR+TXV+ furnace: A80UH1E070A12AHRI reference: 21173436716.408.0080002.04EPA 2464450
EAH1P30B*+TDR+TXV+ furnace: A96UH1E070B12AHRI reference: 21173484116.407.8077002.00EPA 2464474
EAH1P24B*+TDR+TXV+ furnace: A80UH1E070B12AHRI reference: 21173452216.408.1082002.10EPA 2464873
EAH1P30B*+TDR+TXV+ furnace: A93UH1E030B12AHRI reference: 21173476716.407.8078001.98EPA 2464876
EAH1P24A*+TDR+TXV+ furnace: A80UH1E045A12AHRI reference: 21173435016.408.0080002.06EPA 2465304
EAH1P24A*+TDR+TXV+ furnace: A80UH2E070A12AHRI reference: 21173432616.408.1082002.06EPA 2466170
EAH1P24B*+TDR+TXV+ furnace: A93UH1E070B12AHRI reference: 21173457916.408.1082002.10EPA 2466177
EAH1P24B*+TDR+TXV+ furnace: A80UH2E090B12AHRI reference: 21173444116.408.1082002.08EPA 2466609