AIREASE / AIR-SOURCE HEAT PUMP

4SHP17LE118P-**A

4HSP17LE Series · 4SHP17 SERIES · 4SHP17LE SERIES · 4SHP17LE Series · 4SHP17LE1 Series · source records, page 15

331 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity18,000BTU/h

Each efficiency range summarizes published EPA records for 4SHP17LE118P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 331 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8331 / 331
EER2 · BTU/Wh12.2–14331 / 331
HSPF2 · BTU/Wh7.8–8.5331 / 331
Cooling capacity · BTU/h18,000331 / 331
Heating capacity at 47°F / 8.3°C · BTU/h16,000–18,000331 / 331
Heating capacity at 17°F / −8.3°C · BTU/h10,200–12,100331 / 331
Heating capacity at 5°F / −15°C · BTU/h7,500–9,700331 / 331
COP at 5°F / −15°C1.9–2.16331 / 331
Equipment / loop typeHP - Split System331 / 331
Refrigerant / source-reported GWPR-410A (GWP:2088)331 / 331
Compressor stagingSingle stage331 / 331
Connected capabilityNo331 / 331

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EC24BX-0*+TDR+ furnace: A93UH1E030B12AHRI reference: 21471522916.008.1084002.08EPA 3489451
7ED30/36BX-0*+TDR+ furnace: A97DF2E045B12AHRI reference: 21471519516.008.3089002.08EPA 3489544
7EC24AX-0*+TDR+ furnace: A80UH2E045A12AHRI reference: 21471521316.008.1084002.06EPA 3489569
7EC24AX-0*+TDR+ furnace: A80US2V070A12AHRI reference: 21471521816.008.1085002.06EPA 3489576
7EC24AX-0*+TDR+ furnace: A80US2V070A12LAHRI reference: 21471521916.008.1085002.06EPA 3489578
7EC24BX-0*+TDR+ furnace: A97US2V045B12S*AHRI reference: 21471522416.008.1084002.06EPA 3489584
7EC24BX-0*+TDR+ furnace: A97UH2E070B12AHRI reference: 21471522516.008.0083002.12EPA 3489586
7EC30AX-0*+TDR+ furnace: A80UH1E040A12XAHRI reference: 21471524216.007.8075001.92EPA 3491790
7EC24BX-0*+TDR+ furnace: A93UH1E045B12AHRI reference: 21471523016.008.0082002.06EPA 3491800
7EC24BX-0*+TDR+ furnace: A96UH1E045B12AHRI reference: 21471523316.008.0082002.04EPA 3491802
7EC24BX-0*+TDR+ furnace: A96UH1E070B12AHRI reference: 21471523416.008.0082002.08EPA 3491803
7AH1AE24PX-0*AHRI reference: 21486607716.008.1085002.14EPA 3553688
7AH1AV18PX-0*AHRI reference: 21486597116.008.1082002.08EPA 3553885
EA(C;U)1P24A+TDR+TXV+ furnace: A80UH1E040A12XAHRI reference: 21033018815.807.8080002.04EPA 2457734
EA(C;U)1P24A+TDR+TXV+ furnace: A80UH1E060A12XAHRI reference: 21033018915.807.8080002.04EPA 2457738
EAC4X24A+TDR+ furnace: A80UH1E060A12XAHRI reference: 21166281015.807.8080002.04EPA 2458964
EAC4X24A+TDR+ furnace: A80UH1E040A12XAHRI reference: 21166280915.807.8080002.04EPA 2458967
EAD4X-30/36B+TDR+ furnace: A80DS2V090B16AHRI reference: 21326492815.808.5096002.04EPA 2840004
7ED30/36BX-0*+TDR+ furnace: A80DS2V090B16AHRI reference: 21471520415.808.5096002.04EPA 3489097
7EC24AX-0*+TDR+ furnace: A80UH1E060A12XAHRI reference: 21471521215.807.8080002.04EPA 3489342

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →