AIREASE / AIR-SOURCE HEAT PUMP

4SHP17LE118P-**A

4HSP17LE Series · 4SHP17 SERIES · 4SHP17LE SERIES · 4SHP17LE Series · 4SHP17LE1 Series

331 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity18,000BTU/h

Each efficiency range summarizes published EPA records for 4SHP17LE118P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 331 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8331 / 331
EER2 · BTU/Wh12.2–14331 / 331
HSPF2 · BTU/Wh7.8–8.5331 / 331
Cooling capacity · BTU/h18,000331 / 331
Heating capacity at 47°F / 8.3°C · BTU/h16,000–18,000331 / 331
Heating capacity at 17°F / −8.3°C · BTU/h10,200–12,100331 / 331
Heating capacity at 5°F / −15°C · BTU/h7,500–9,700331 / 331
COP at 5°F / −15°C1.9–2.16331 / 331
Equipment / loop typeHP - Split System331 / 331
Refrigerant / source-reported GWPR-410A (GWP:2088)331 / 331
Compressor stagingSingle stage331 / 331
Connected capabilityNo331 / 331

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA(C;U)1P30A+TDR+TXV+ furnace: A80UH2E070A12AHRI reference: 21033021716.808.0076001.98EPA 2456402
EA(C;U)1P30B+TDR+TXV+ furnace: A80UH1E070B12AHRI reference: 21166277416.807.8077001.98EPA 2456620
EA(C;U)1P30A+TDR+TXV+ furnace: A80UH2E090B12AHRI reference: 21033022916.808.0076002.00EPA 2456720
EA(C;U)1P30A+TDR+TXV+ furnace: A80UH1E045A12AHRI reference: 21033021416.807.8077002.00EPA 2456730
EAC4X30A+TDR+ furnace: A80UH2E070A12AHRI reference: 21166283916.808.0076001.98EPA 2456772
EAC4X30A+TDR+ furnace: A80US2V060A12XAHRI reference: 21166284216.808.0079002.02EPA 2456773
EAC4X30A+TDR+ furnace: A80UH1E045A12AHRI reference: 21166284016.807.8077002.00EPA 2456775
EAC4X30B+TDR+ furnace: A80UH2E090B12AHRI reference: 21166284516.808.0076002.00EPA 2456776
EA(C;U)1P30B+TDR+TXV+ furnace: A80UH2E090B12AHRI reference: 21166276816.808.0076002.00EPA 2457191
EA(C;U)1P30A+TDR+TXV+ furnace: A80US2V060A12XAHRI reference: 21033021916.808.0079002.02EPA 2457331
EA(C;U)1P30B+TDR+TXV+ furnace: A80US2V080B16XAHRI reference: 21166278216.808.1078001.98EPA 2457368
EA(C;U)1P30B+TDR+TXV+ furnace: A80US2V090B12AHRI reference: 21166278316.808.1080002.02EPA 2457369
EA(C;U)1P30B+TDR+TXV+ furnace: A97US2V040B12XAHRI reference: 21166278516.808.0078002.00EPA 2457371
EA(C;U)1P30A+TDR+TXV+ furnace: A97US2V040B12XAHRI reference: 21033023416.808.0078002.00EPA 2457910
EA(C;U)1P30A+TDR+TXV+ furnace: A80US2V090B12AHRI reference: 21033024016.808.1080002.02EPA 2458279
EA(C;U)1P30A+TDR+TXV+ furnace: A80UH1E070B12AHRI reference: 21033022216.807.8077001.98EPA 2458280
EA(C;U)1P30A+TDR+TXV+ furnace: A97USMV070B12AHRI reference: 21033023616.808.0078002.00EPA 2458295
EAC4X30B+TDR+ furnace: A80UH1E070B12AHRI reference: 21166285116.807.8077001.98EPA 2458656
EAC4X30B+TDR+ furnace: A80US2V090B12AHRI reference: 21166286016.808.1080002.02EPA 2458662
EAC4X30B+TDR+ furnace: A80US2V080B16XAHRI reference: 21166285916.808.1078001.98EPA 2458663

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →