ACIQ / AIR-SOURCE HEAT PUMP

R5H5S36*K*AAA*

15 SEER2 HP

26 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.5BTU/Wh
HSPF2 range7.8–8BTU/Wh
Cooling capacity33,800–36,800BTU/h

Each efficiency range summarizes published EPA records for R5H5S36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 26 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.526 / 26
EER2 · BTU/Wh11.7–1326 / 26
HSPF2 · BTU/Wh7.8–826 / 26
Cooling capacity · BTU/h33,800–36,80026 / 26
Heating capacity at 47°F / 8.3°C · BTU/h33,200–36,20026 / 26
Heating capacity at 17°F / −8.3°C · BTU/h21,000–22,80026 / 26
Heating capacity at 5°F / −15°C · BTU/h16,100–18,10026 / 26
COP at 5°F / −15°C2–2.226 / 26
Equipment / loop typeHP - Split System26 / 26
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)26 / 26
Compressor stagingSingle stage26 / 26
Connected capabilityNo26 / 26

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
FTMA5B48L0C*AHRI reference: 21662913015.507.80167002.18EPA 3959567
F5MA5*48L*C*AHRI reference: 21662913815.507.80174002.18EPA 3959580
FMA5X36**AL*AHRI reference: 21663062615.507.80170002.00EPA 3960508
FHMA5*48L*C*AHRI reference: 21773892415.507.80174002.18EPA 4513541
EA*5X37M21A*+ furnace: *80CSU0601716A*AHRI reference: 21662820215.207.80171002.16EPA 3959388
EA*5X37M21A*+ furnace: *80MS(N,L)0902120A*AHRI reference: 21662820615.207.80179002.20EPA 3959390
EA*5X43M21A*+ furnace: *92MSN1002120A*AHRI reference: 21662828015.207.80179002.20EPA 3959396
EA*5X43M21A*+ furnace: *80MS(N,L)1102120A*AHRI reference: 21662826615.207.80180002.20EPA 3959397
EA*5X43M21A*+ furnace: *80CSU1002120A*AHRI reference: 21662826215.207.80176002.18EPA 3959398
EA*5X43M21A*+ furnace: *80CSU0601716A*AHRI reference: 21662826015.207.80170002.18EPA 3959400
EA*5X43M21A*+ furnace: *80MS(N,L)0902120A*AHRI reference: 21662826415.207.80179002.20EPA 3959402
EA*5X48M21A*+ furnace: *80MS(N,L)0902120A*AHRI reference: 21662830215.207.80175002.18EPA 3959535
EA*5X48M21A*+ furnace: *80MS(N,L)1102120A*AHRI reference: 21662830415.207.80176002.20EPA 3959537
EA*5X48M21A*+ furnace: *80MSU0802120A*AHRI reference: 21662831615.207.80173002.20EPA 3959539
EA*5X48M21A*+ furnace: *80VTL0902120B*AHRI reference: 21662832415.207.80175002.18EPA 3959540
EA*5X48M21A*+ furnace: *80VSL0902120B*AHRI reference: 21662830815.207.80175002.18EPA 3959543
EA*5X48M21A*+ furnace: *80MSU0601716A*AHRI reference: 21662831415.207.80176002.18EPA 3959544
EA*5X48M21A*+ furnace: *80CTL1102120B*AHRI reference: 21662832215.207.80175002.18EPA 3959546
EA*5X48M21A*+ furnace: *92MSN1002120A*AHRI reference: 21662833415.207.80176002.18EPA 3959548
EA*5X48M21A*+ furnace: *96VTN1002122B*AHRI reference: 21662835215.207.80175002.20EPA 3959549

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →