ACIQ / AIR-SOURCE HEAT PUMP

R5H5S24*K*AAA*

15 SEER2 HP

182 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–24,400BTU/h

Each efficiency range summarizes published EPA records for R5H5S24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 182 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5182 / 182
EER2 · BTU/Wh11.7–13182 / 182
HSPF2 · BTU/Wh7.8–8.5182 / 182
Cooling capacity · BTU/h22,200–24,400182 / 182
Heating capacity at 47°F / 8.3°C · BTU/h21,600–24,000182 / 182
Heating capacity at 17°F / −8.3°C · BTU/h14,200–15,200182 / 182
Heating capacity at 5°F / −15°C · BTU/h10,800–11,900182 / 182
COP at 5°F / −15°C1.96–2.26182 / 182
Equipment / loop typeHP - Split System182 / 182
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)182 / 182
Compressor stagingSingle stage182 / 182
Connected capabilityNo182 / 182

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
FMA5X30**AL*AHRI reference: 21663061616.508.50116002.26EPA 3960504
EA*5X37M21A*+ furnace: *97VTN1002120A*AHRI reference: 21581801916.008.00115002.10EPA 3653682
EA*5X37M21A*+ furnace: *97VTN1002122A*AHRI reference: 21581802116.008.00114002.10EPA 3653684
EA*5X37M21A*+ furnace: *96CTN0802120B*AHRI reference: 21587130516.007.80114001.96EPA 3721887
EVD5X31M17A*+ furnace: *80VSL0901716B*AHRI reference: 21663013416.007.80113001.98EPA 3960307
EA*5X25M17A*+ furnace: *80MSU0401712A*AHRI reference: 21663038416.007.80113002.12EPA 3960325
EA*5X25M17A*+ furnace: *80MSU0601716A*AHRI reference: 21663038616.007.80112002.12EPA 3960327
EA*5X25M17A*+ furnace: *80CTL0701412B*AHRI reference: 21663038816.007.80114002.12EPA 3960396
EA*5X37M21A*+ furnace: *80CSU0401712A*AHRI reference: 21663039616.007.80112002.12EPA 3960405
EA*5X37M21A*+ furnace: *80CSU0802120A*AHRI reference: 21663039816.007.80113002.14EPA 3960414
EA*5X37M21A*+ furnace: *80VTL1102122B*AHRI reference: 21663042216.007.80115002.14EPA 3960421
EA*5X37M21A*+ furnace: *80CTL0902120B*AHRI reference: 21663042016.007.80115002.14EPA 3960425
EA*5X37M21A*+ furnace: *95CSU1002122B*AHRI reference: 21663042416.007.80116002.14EPA 3960426
EA*5X37M21A*+ furnace: *97CMN1002122B*AHRI reference: 21663042816.007.80115002.14EPA 3960430
EA*5X37M21A*+ furnace: *97CMN0802120B*AHRI reference: 21663042616.007.80115002.14EPA 3960431
EA*5X37M21A*+ furnace: *95MSU1002120A*AHRI reference: 21663044216.007.80115002.14EPA 3960439
EVM5X31M17A*+ furnace: *80MSU0601716A*AHRI reference: 21663046016.007.80112001.98EPA 3960447
EA*5X37M21A*+ furnace: *96CTN1002122B*AHRI reference: 21663044616.007.80115002.14EPA 3960450
EVM5X32M17A*+ furnace: *80VSL0901716B*AHRI reference: 21663047616.007.80114001.98EPA 3960459
EVM5X32M17A*+ furnace: *80MS(N,L)0901714A*AHRI reference: 21663046816.007.80112001.98EPA 3960462