ACIQ / AIR-SOURCE HEAT PUMP

N5H9V60*K*AAA*

Performance 19 SEER2 VS HP · source records, page 7

211 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range8–9BTU/Wh
Cooling capacity54,000–57,500BTU/h

Each efficiency range summarizes published EPA records for N5H9V60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 211 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17211 / 211
EER2 · BTU/Wh10–12211 / 211
HSPF2 · BTU/Wh8–9211 / 211
Cooling capacity · BTU/h54,000–57,500211 / 211
Heating capacity at 47°F / 8.3°C · BTU/h57,500–62,000211 / 211
Heating capacity at 17°F / −8.3°C · BTU/h48,000–50,500211 / 211
Heating capacity at 5°F / −15°C · BTU/h39,000–42,000211 / 211
COP at 5°F / −15°C1.94–2.16211 / 211
Equipment / loop typeHP - Split System211 / 211
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)211 / 211
Compressor stagingContinuously variable211 / 211
Connected capabilityNo211 / 211

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVM5X60M21A*+ furnace: *96CTN0802120B*AHRI reference: 21801766815.508.00395001.96EPA 4567431
EVD5X60M21A*+ furnace: *95MSU1002122A*AHRI reference: 21801801715.508.00395001.96EPA 4567434
EVD5X60M21A*+ furnace: *97VTN0802120A*AHRI reference: 21801804515.508.00400001.94EPA 4567442
EVD5X60M21A*+ furnace: *97VTN1002120A*AHRI reference: 21801804915.508.00400001.96EPA 4567443
EVM5X60M21A*+ furnace: *97CTN0802120A*AHRI reference: 21801767515.508.00395001.96EPA 4567451
EVM5X60M21A*+ furnace: *96VTN0802120B*AHRI reference: 21801768415.508.00395001.96EPA 4567453
EVD5X60M21A*+ furnace: *80CSU0802120B*AHRI reference: 21801794615.508.00395001.96EPA 4567472
EVD5X60M21A*+ furnace: *80VSL0902120B*AHRI reference: 21801795115.508.00395001.94EPA 4567474
EVD5X60M21A*+ furnace: *80MSU0601716A*AHRI reference: 21801795415.508.00395001.94EPA 4567476
EVD5X60M21A*+ furnace: *80MSU1002120A*AHRI reference: 21801796115.508.00395001.94EPA 4567480
EVD5X60M21A*+ furnace: *80VTL0902120B*AHRI reference: 21801797515.508.00395001.94EPA 4567484
EVD5X60M21A*+ furnace: *80CTL1102120B*AHRI reference: 21801797115.508.00395001.94EPA 4567485
EVD5X60M21A*+ furnace: *95CSU1002122B*AHRI reference: 21801798315.508.00400001.94EPA 4567489
EVD5X60M21A*+ furnace: *96VSN0802120B*AHRI reference: 21801800115.508.00400001.94EPA 4567494
EVD5X60M21A*+ furnace: *96VSN1002120B*AHRI reference: 21801800515.508.00400001.96EPA 4567495
EVM5X61M24A*+ furnace: *80CSU0802120B*AHRI reference: 21801779415.508.00405001.98EPA 4567496
EVM5X61M24A*+ furnace: *80VSL0902120B*AHRI reference: 21801780215.508.00410001.96EPA 4567497
EVM5X61M24A*+ furnace: *80VSL1102122B*AHRI reference: 21801780615.508.00410001.96EPA 4567498
EVM5X61M24A*+ furnace: *80CTL1352422B*AHRI reference: 21801783115.508.00405001.96EPA 4567507
EVM5X61M24A*+ furnace: *80VTL0902120B*AHRI reference: 21801783415.508.00410001.96EPA 4567510

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →