ACIQ / AIR-SOURCE HEAT PUMP

N5H9V60*K*AAA*

Performance 19 SEER2 VS HP · source records, page 4

211 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range8–9BTU/Wh
Cooling capacity54,000–57,500BTU/h

Each efficiency range summarizes published EPA records for N5H9V60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 211 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17211 / 211
EER2 · BTU/Wh10–12211 / 211
HSPF2 · BTU/Wh8–9211 / 211
Cooling capacity · BTU/h54,000–57,500211 / 211
Heating capacity at 47°F / 8.3°C · BTU/h57,500–62,000211 / 211
Heating capacity at 17°F / −8.3°C · BTU/h48,000–50,500211 / 211
Heating capacity at 5°F / −15°C · BTU/h39,000–42,000211 / 211
COP at 5°F / −15°C1.94–2.16211 / 211
Equipment / loop typeHP - Split System211 / 211
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)211 / 211
Compressor stagingContinuously variable211 / 211
Connected capabilityNo211 / 211

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X61M21A*+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 21801851716.009.00410002.14EPA 4567690
EA*5X61M21A*+ furnace: *80VTL1102122B*AHRI reference: 21801852516.009.00405002.14EPA 4567718
EA*5X61M21A*+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 21801854416.008.50410002.00EPA 4567727
EA*5X61M21A*+ furnace: *96VSN1002120B*Cold climate designationAHRI reference: 21801855216.008.50410002.05EPA 4567732
EA*5X61M21A*+ furnace: *95MSU1002122A*Cold climate designationAHRI reference: 21801856916.008.50410002.00EPA 4567737
F5MA5*60L*D*AHRI reference: 21801890516.009.00400002.16EPA 4567745
EA*5X60M24A*+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 21801891716.009.00410002.12EPA 4567752
EA*5X61M21A*+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 21801892216.008.50410002.00EPA 4567755
EA*5X61M21A*+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 21801892716.008.50410002.00EPA 4567758
EA*5X61M21A*+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 21801858116.008.50410002.00EPA 4567771
EA*5X61M21A*+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 21801858816.008.50410002.00EPA 4567775
EA*5X61M21A*+ furnace: *96VTN1002122B*Cold climate designationAHRI reference: 21801860116.009.00410002.14EPA 4567780
EA*5X61M21A*+ furnace: *97VTN1002120A*Cold climate designationAHRI reference: 21801861316.009.00410002.14EPA 4567785
EA*5X61M21A*+ furnace: *97VTN1002122A*Cold climate designationAHRI reference: 21801862016.009.00410002.14EPA 4567789
EA*5X61M24A*+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 21801863016.008.50410002.00EPA 4567792
EA*5X61M24A*+ furnace: *80VSL0902120B*Cold climate designationAHRI reference: 21801863416.009.00410002.14EPA 4567793
EA*5X61M24A*+ furnace: *80VSL1102122B*AHRI reference: 21801864316.009.00405002.14EPA 4567810
EA*5X61M24A*+ furnace: *80VSL1352422B*AHRI reference: 21801864716.009.00405002.12EPA 4567812
EA*5X61M24A*+ furnace: *80MSU1002120A*Cold climate designationAHRI reference: 21801865716.008.50410002.00EPA 4567817
EA*5X61M24A*+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 21801866116.008.50410002.00EPA 4567819

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.