Performance 19 SEER2 VS HP · source records, page 7
490 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H9V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 490 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 490 / 490 |
| EER2 · BTU/Wh | 10–12.5 | 490 / 490 |
| HSPF2 · BTU/Wh | 8.5–10 | 490 / 490 |
| Cooling capacity · BTU/h | 44,500–49,500 | 490 / 490 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,500–55,000 | 490 / 490 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 38,500–47,000 | 490 / 490 |
| Heating capacity at 5°F / −15°C · BTU/h | 36,000–41,500 | 490 / 490 |
| COP at 5°F / −15°C | 1.95–2.32 | 490 / 490 |
| Equipment / loop type | HP - Split System | 490 / 490 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 490 / 490 |
| Compressor staging | Continuously variable | 490 / 490 |
| Connected capability | No | 490 / 490 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVD5X60M21A*+ furnace: *80MSU1002120A*Cold climate designationAHRI reference: 218021197 | 16.50 | 9.00 | 40500 | 2.10 | EPA 4568869 → |
EVD5X60M21A*+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 218021200 | 16.50 | 9.50 | 40000 | 2.24 | EPA 4568871 → |
EVD5X60M21A*+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 218021201 | 16.50 | 9.50 | 40500 | 2.24 | EPA 4568872 → |
EVD5X60M21A*+ furnace: *80VTL0902120B*Cold climate designationAHRI reference: 218021203 | 16.50 | 9.50 | 40500 | 2.22 | EPA 4568873 → |
EVD5X60M21A*+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 218021208 | 16.50 | 9.00 | 40000 | 2.10 | EPA 4568876 → |
EVD5X60M21A*+ furnace: *95MSU1002122A*Cold climate designationAHRI reference: 218021222 | 16.50 | 9.00 | 40000 | 2.10 | EPA 4568883 → |
EVD5X61M21A*+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 218021243 | 16.50 | 9.00 | 40500 | 2.10 | EPA 4568893 → |
EVD5X61M21A*+ furnace: *80VSL0902120B*Cold climate designationAHRI reference: 218021244 | 16.50 | 9.50 | 40500 | 2.24 | EPA 4568895 → |
EVD5X61M21A*+ furnace: *80VSL1102122B*Cold climate designationAHRI reference: 218021246 | 16.50 | 9.50 | 40500 | 2.24 | EPA 4568896 → |
EVD5X61M21A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 218021248 | 16.50 | 9.00 | 40500 | 2.10 | EPA 4568897 → |
EVD5X61M21A*+ furnace: *80VTL0902120B*Cold climate designationAHRI reference: 218021258 | 16.50 | 9.50 | 40500 | 2.24 | EPA 4568901 → |
EVD5X61M21A*+ furnace: *80VTL1102122B*Cold climate designationAHRI reference: 218021260 | 16.50 | 9.50 | 40000 | 2.24 | EPA 4568902 → |
EVD5X49M24A*+ furnace: *96VTN1002122B*Cold climate designationAHRI reference: 218021177 | 16.50 | 9.50 | 40500 | 2.24 | EPA 4568914 → |
EVD5X61M21A*+ furnace: *80MSU1002120A*Cold climate designationAHRI reference: 218021251 | 16.50 | 9.00 | 40500 | 2.10 | EPA 4568917 → |
EVD5X61M24A*+ furnace: *80VTL1102122B*Cold climate designationAHRI reference: 218016375 | 16.50 | 9.50 | 40500 | 2.24 | EPA 4568967 → |
EVD5X61M24A*+ furnace: *97VTN1002122A*Cold climate designationAHRI reference: 218016415 | 16.50 | 9.50 | 40500 | 2.24 | EPA 4568971 → |
EA*5X48M21A*+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 218016418 | 16.50 | 9.00 | 36800 | 2.10 | EPA 4568972 → |
EA*5X48M21A*+ furnace: *80VSL0902120B*Cold climate designationAHRI reference: 218016425 | 16.50 | 9.00 | 36800 | 2.10 | EPA 4568974 → |
EA*5X48M21A*+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 218016449 | 16.50 | 9.00 | 37000 | 2.08 | EPA 4568975 → |
EA*5X60M24A*+ furnace: *80VTL1102122B*Cold climate designationAHRI reference: 218016499 | 16.50 | 9.00 | 37000 | 2.08 | EPA 4568980 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.