ACIQ / AIR-SOURCE HEAT PUMP

N5H9V36*K*AAA*

Performance 19 SEER2 VS HP · source records, page 20

448 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–9BTU/Wh
Cooling capacity33,400–37,600BTU/h

Each efficiency range summarizes published EPA records for N5H9V36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 448 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17448 / 448
EER2 · BTU/Wh10.5–12.5448 / 448
HSPF2 · BTU/Wh7.8–9448 / 448
Cooling capacity · BTU/h33,400–37,600448 / 448
Heating capacity at 47°F / 8.3°C · BTU/h31,800–37,400448 / 448
Heating capacity at 17°F / −8.3°C · BTU/h31,800–37,600448 / 448
Heating capacity at 5°F / −15°C · BTU/h24,600–26,600448 / 448
COP at 5°F / −15°C1.9–2.18448 / 448
Equipment / loop typeHP - Split System448 / 448
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)448 / 448
Compressor stagingContinuously variable448 / 448
Connected capabilityNo448 / 448

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X43M21A*+ furnace: *95CSU0802120B*AHRI reference: 21801833015.209.00248002.08EPA 4567610 →
EA*5X43M21A*+ furnace: *97CMN0801714B*AHRI reference: 21801834015.209.00250002.06EPA 4567614 →
EA*5X43M21A*+ furnace: *96VSN0801716B*AHRI reference: 21801835215.209.00250002.06EPA 4567618 →
EA*5X43M21A*+ furnace: *96CTN0801714B*AHRI reference: 21801837315.209.00250002.06EPA 4567624 →
EA*5X43M21A*+ furnace: *96VTN0801716B*AHRI reference: 21801840115.209.00250002.06EPA 4567635 →
EA*5X43M21A*+ furnace: *96VTN1002122B*AHRI reference: 21801841115.208.50246001.96EPA 4567640 →
EA*5X43M21A*+ furnace: *97VTN0801716A*AHRI reference: 21801841815.209.00250002.06EPA 4567641 →
EA*5X43M21A*+ furnace: *97VTN1002122A*AHRI reference: 21801842315.208.50246001.96EPA 4567644 →
EA*5X48M21A*+ furnace: *80VSL0701716B*AHRI reference: 21801845015.209.00254002.08EPA 4567657 →
EA*5X48M21A*+ furnace: *80CTL0701716B*AHRI reference: 21801849415.209.00254002.06EPA 4567678 →
EA*5X48M21A*+ furnace: *80CTL0702120B*AHRI reference: 21801850815.209.00252002.06EPA 4567685 →
EA*5X48M21A*+ furnace: *80VTL0701716B*AHRI reference: 21801852715.209.00254002.06EPA 4567719 →
EA*5X48M21A*+ furnace: *95CSU0802120B*AHRI reference: 21801854615.209.00252002.06EPA 4567728 →
EA*5X48M21A*+ furnace: *96VSN0802120B*AHRI reference: 21801858515.209.00252002.06EPA 4567773 →
EA*5X48M21A*+ furnace: *97VTN0802120A*AHRI reference: 21801869415.209.00252002.06EPA 4567834 →
EVM5X43M21A*+ furnace: *96VSN0401712B*Cold climate designationAHRI reference: 21801960515.208.50254002.06EPA 4567996 →
EVM5X36M17A*+ furnace: *80VSL0701412B*Cold climate designationAHRI reference: 21801950115.208.50258002.02EPA 4568062 →
EVM5X36M17A*+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 21801951515.208.50260002.02EPA 4568064 →
EVM5X36M17A*+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 21801952315.208.50260002.02EPA 4568066 →
EVM5X36M17A*+ furnace: *95MSU0601716A*Cold climate designationAHRI reference: 21801952915.208.50260002.00EPA 4568067 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →