ACIQ / AIR-SOURCE HEAT PUMP

N5H9V36*K*AAA*

Performance 19 SEER2 VS HP · source records, page 12

448 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–9BTU/Wh
Cooling capacity33,400–37,600BTU/h

Each efficiency range summarizes published EPA records for N5H9V36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 448 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17448 / 448
EER2 · BTU/Wh10.5–12.5448 / 448
HSPF2 · BTU/Wh7.8–9448 / 448
Cooling capacity · BTU/h33,400–37,600448 / 448
Heating capacity at 47°F / 8.3°C · BTU/h31,800–37,400448 / 448
Heating capacity at 17°F / −8.3°C · BTU/h31,800–37,600448 / 448
Heating capacity at 5°F / −15°C · BTU/h24,600–26,600448 / 448
COP at 5°F / −15°C1.9–2.18448 / 448
Equipment / loop typeHP - Split System448 / 448
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)448 / 448
Compressor stagingContinuously variable448 / 448
Connected capabilityNo448 / 448

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X48M21A*+ furnace: *97CMN0802120B*AHRI reference: 21801856815.509.00252002.06EPA 4567736
EA*5X48M21A*+ furnace: *97CMN1002122B*AHRI reference: 21801857115.509.00252002.08EPA 4567738
EA*5X48M21A*+ furnace: *96VSN1002120B*AHRI reference: 21801859015.509.00252002.06EPA 4567776
EA*5X48M21A*+ furnace: *95MSU1002120A*AHRI reference: 21801861415.509.00252002.08EPA 4567786
EA*5X48M21A*+ furnace: *95MSU1002122A*AHRI reference: 21801861815.509.00252002.06EPA 4567788
EA*5X48M21A*+ furnace: *96CTN1002122B*AHRI reference: 21801863615.509.00252002.08EPA 4567794
EA*5X48M21A*+ furnace: *97CTN0802120A*AHRI reference: 21801864515.509.00252002.06EPA 4567811
EA*5X48M21A*+ furnace: *97CTN1002122A*AHRI reference: 21801864815.509.00252002.08EPA 4567813
EA*5X48M21A*+ furnace: *96VTN1002120B*AHRI reference: 21801867315.509.00252002.08EPA 4567823
EA*5X48M21A*+ furnace: *97VTN1002120A*AHRI reference: 21801869715.509.00252002.08EPA 4567837
EVM5X36M17A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 21801950815.508.50256002.00EPA 4568061
EVM5X36M17A*+ furnace: *80CTL0701412B*Cold climate designationAHRI reference: 21801951215.508.50258002.02EPA 4568063
EVM5X36M17A*+ furnace: *80VTL0701716B*Cold climate designationAHRI reference: 21801951715.508.50260002.00EPA 4568065
EVM5X48M21A*+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 21801966715.508.50260002.00EPA 4568072
FTMA5B36L0C*Cold climate designationAHRI reference: 21801949615.509.00254002.08EPA 4568184
EVM5X36M17A*+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 21801949815.508.50258002.00EPA 4568185
EVM5X36M17A*+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 21801950015.508.50256002.05EPA 4568186
EVM5X36M17A*+ furnace: *80VSL0701716B*Cold climate designationAHRI reference: 21801950315.508.50258002.02EPA 4568187
EVM5X36M17A*+ furnace: *80MSU0401712A*Cold climate designationAHRI reference: 21801950715.508.50258002.00EPA 4568189
EVM5X49M21A*+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 21801972815.508.50264002.00EPA 4568194

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →