ACIQ / AIR-SOURCE HEAT PUMP

N5H9V36*K*AAA*

Performance 19 SEER2 VS HP · source records, page 10

448 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–9BTU/Wh
Cooling capacity33,400–37,600BTU/h

Each efficiency range summarizes published EPA records for N5H9V36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 448 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17448 / 448
EER2 · BTU/Wh10.5–12.5448 / 448
HSPF2 · BTU/Wh7.8–9448 / 448
Cooling capacity · BTU/h33,400–37,600448 / 448
Heating capacity at 47°F / 8.3°C · BTU/h31,800–37,400448 / 448
Heating capacity at 17°F / −8.3°C · BTU/h31,800–37,600448 / 448
Heating capacity at 5°F / −15°C · BTU/h24,600–26,600448 / 448
COP at 5°F / −15°C1.9–2.18448 / 448
Equipment / loop typeHP - Split System448 / 448
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)448 / 448
Compressor stagingContinuously variable448 / 448
Connected capabilityNo448 / 448

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X43M21A*+ furnace: *80CSU0401712B*AHRI reference: 21801826115.509.00248002.06EPA 4567586
EA*5X43M21A*+ furnace: *80CSU0601716B*AHRI reference: 21801826215.509.00246002.06EPA 4567587
EA*5X43M21A*+ furnace: *80MSU0601716A*AHRI reference: 21801828715.509.00246002.04EPA 4567588
EA*5X43M21A*+ furnace: *80VSL0902120B*AHRI reference: 21801827915.509.00248002.08EPA 4567592
EA*5X43M21A*+ furnace: *80VSL1102122B*AHRI reference: 21801828115.508.50246001.96EPA 4567593
EA*5X43M21A*+ furnace: *80MSU0401712A*AHRI reference: 21801828615.509.00248002.06EPA 4567594
EA*5X43M21A*+ furnace: *80CSU1002120B*AHRI reference: 21801826915.509.00246002.06EPA 4567595
EA*5X43M21A*+ furnace: *80VSL0701716B*AHRI reference: 21801827215.509.00248002.06EPA 4567596
EA*5X43M21A*+ furnace: *80VSL0901716B*AHRI reference: 21801827515.509.00248002.08EPA 4567598
EA*5X43M21A*+ furnace: *80CTL0702120B*AHRI reference: 21801830515.509.00248002.06EPA 4567601
EA*5X43M21A*+ furnace: *80CTL0902120B*AHRI reference: 21801831315.509.00248002.06EPA 4567605
EA*5X43M21A*+ furnace: *80CTL1102120B*AHRI reference: 21801831515.509.00246002.06EPA 4567606
EA*5X43M21A*+ furnace: *80VTL0701716B*AHRI reference: 21801831815.509.00248002.06EPA 4567607
EA*5X43M21A*+ furnace: *80VTL0902120B*AHRI reference: 21801832115.509.00248002.08EPA 4567608
EA*5X43M21A*+ furnace: *95CSU1002122B*AHRI reference: 21801833315.509.00246002.06EPA 4567612
EA*5X43M21A*+ furnace: *97CMN1002122B*AHRI reference: 21801834515.509.00248002.06EPA 4567616
EA*5X43M21A*+ furnace: *96VSN0802120B*AHRI reference: 21801835515.509.00248002.08EPA 4567619
EA*5X43M21A*+ furnace: *95MSU1002120A*AHRI reference: 21801836715.509.00246002.06EPA 4567621
EA*5X43M21A*+ furnace: *95MSU1002122A*AHRI reference: 21801837015.509.00248002.06EPA 4567623
EA*5X43M21A*+ furnace: *96CTN0802120B*AHRI reference: 21801837815.509.00248002.08EPA 4567626

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →