Performance 19 SEER2 VS HP · source records, page 20
1,067 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H9V24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 1,067 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 1,067 / 1,067 |
| EER2 · BTU/Wh | 11.5–14 | 1,067 / 1,067 |
| HSPF2 · BTU/Wh | 8–10 | 1,067 / 1,067 |
| Cooling capacity · BTU/h | 22,800–25,400 | 1,067 / 1,067 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 24,000–25,800 | 1,067 / 1,067 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 19,900–25,200 | 1,067 / 1,067 |
| Heating capacity at 5°F / −15°C · BTU/h | 20,600–22,200 | 1,067 / 1,067 |
| COP at 5°F / −15°C | 1.74–2.02 | 1,067 / 1,067 |
| Equipment / loop type | HP - Split System | 1,067 / 1,067 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 1,067 / 1,067 |
| Compressor staging | Continuously variable | 1,067 / 1,067 |
| Connected capability | No | 1,067 / 1,067 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X25M17A*+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 218018627 | 18.50 | 10.00 | 21200 | 2.00 | EPA 4567791 → |
EA*5X25M17A*+ furnace: *96VSN0601716B*Cold climate designationAHRI reference: 218018637 | 18.50 | 10.00 | 21200 | 1.98 | EPA 4567795 → |
EA*5X25M17A*+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 218018642 | 18.50 | 10.00 | 21200 | 1.98 | EPA 4567809 → |
EA*5X25M17A*+ furnace: *96VTN0601716B*Cold climate designationAHRI reference: 218018652 | 18.50 | 10.00 | 21200 | 1.98 | EPA 4567815 → |
EA*5X25M17A*+ furnace: *97VTN0601716A*Cold climate designationAHRI reference: 218018654 | 18.50 | 10.00 | 21200 | 1.98 | EPA 4567816 → |
EA*5X37M21A*+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 218018664 | 18.50 | 10.00 | 21200 | 1.95 | EPA 4567820 → |
EA*5X37M21A*+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 218018670 | 18.50 | 10.00 | 21200 | 1.96 | EPA 4567822 → |
EA*5X25M17A*+ furnace: *80VSL0901716B*Cold climate designationAHRI reference: 218019055 | 18.50 | 10.00 | 21200 | 1.98 | EPA 4567860 → |
EA*5X37M17A*+ furnace: *80VSL0701412B*Cold climate designationAHRI reference: 218019057 | 18.50 | 9.50 | 21200 | 1.90 | EPA 4567861 → |
EA*5X37M17A*+ furnace: *80VSL0701716B*Cold climate designationAHRI reference: 218019058 | 18.50 | 9.50 | 21200 | 1.90 | EPA 4567862 → |
EA*5X37M21A*+ furnace: *80VSL0902120B*Cold climate designationAHRI reference: 218019060 | 18.50 | 10.00 | 21200 | 2.00 | EPA 4567863 → |
EA*5X37M21A*+ furnace: *80VTL0902120B*Cold climate designationAHRI reference: 218019062 | 18.50 | 10.00 | 21200 | 2.00 | EPA 4567864 → |
EA*5X37M21A*+ furnace: *96VSN0601716B*Cold climate designationAHRI reference: 218019064 | 18.50 | 10.00 | 21200 | 1.98 | EPA 4567866 → |
EA*5X25M17A*+ furnace: *80VSL0701412B*Cold climate designationAHRI reference: 218019144 | 18.50 | 10.00 | 21200 | 2.00 | EPA 4567910 → |
EA*5X25M17A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 218019148 | 18.50 | 9.50 | 21200 | 1.90 | EPA 4567912 → |
EA*5X25M17A*+ furnace: *95MSU0601716A*Cold climate designationAHRI reference: 218019149 | 18.50 | 9.50 | 21200 | 1.90 | EPA 4567913 → |
EA*5X37M17A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 218019155 | 18.50 | 9.50 | 21200 | 1.90 | EPA 4567942 → |
EA*5X37M21A*+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 218019156 | 18.50 | 10.00 | 21200 | 1.98 | EPA 4567943 → |
EA*5X37M21A*+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 218019158 | 18.50 | 10.00 | 21200 | 1.98 | EPA 4567944 → |
EA*5X37M21A*+ furnace: *80VTL0701716B*Cold climate designationAHRI reference: 218019160 | 18.50 | 10.00 | 21200 | 1.98 | EPA 4567945 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.