N5H9V24*K*AAA*
Performance 19 SEER2 VS HP · source records, page 15
1,067 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H9V24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 1,067 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 1,067 / 1,067 |
| EER2 · BTU/Wh | 11.5–14 | 1,067 / 1,067 |
| HSPF2 · BTU/Wh | 8–10 | 1,067 / 1,067 |
| Cooling capacity · BTU/h | 22,800–25,400 | 1,067 / 1,067 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 24,000–25,800 | 1,067 / 1,067 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 19,900–25,200 | 1,067 / 1,067 |
| Heating capacity at 5°F / −15°C · BTU/h | 20,600–22,200 | 1,067 / 1,067 |
| COP at 5°F / −15°C | 1.74–2.02 | 1,067 / 1,067 |
| Equipment / loop type | HP - Split System | 1,067 / 1,067 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 1,067 / 1,067 |
| Compressor staging | Continuously variable | 1,067 / 1,067 |
| Connected capability | No | 1,067 / 1,067 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVD5X37M21A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 218020370 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4568582 → |
EVD5X37M21A*+ furnace: *80MSU0802120A*Cold climate designationAHRI reference: 218020371 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4568583 → |
EVD5X37M21A*+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218020421 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4568584 → |
EVD5X37M21A*+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 218020423 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4568585 → |
EVD5X37M21A*+ furnace: *97CTN0601716A*Cold climate designationAHRI reference: 218020425 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4568586 → |
EVD5X37M21A*+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 218020426 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4568587 → |
EVD5X37M21A*+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 218020429 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4568588 → |
EVD5X37M21A*+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218020428 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4568589 → |
EVD5X37M21A*+ furnace: *96VTN0601716B*Cold climate designationAHRI reference: 218020432 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4568591 → |
EVD5X37M21A*+ furnace: *96VTN0801716B*Cold climate designationAHRI reference: 218020434 | 19.00 | 8.50 | 21400 | 1.88 | EPA 4568592 → |
EVD5X37M21A*+ furnace: *96VTN0802120B*Cold climate designationAHRI reference: 218020435 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4568593 → |
EVD5X37M21A*+ furnace: *96VTN1002122B*Cold climate designationAHRI reference: 218020438 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4568594 → |
EVD5X37M21A*+ furnace: *97VTN0601716A*Cold climate designationAHRI reference: 218020440 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4568595 → |
EVD5X37M21A*+ furnace: *97VTN0801716A*Cold climate designationAHRI reference: 218020442 | 19.00 | 8.50 | 21400 | 1.88 | EPA 4568596 → |
EVD5X37M21A*+ furnace: *97VTN0802120A*Cold climate designationAHRI reference: 218020443 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4568597 → |
EVD5X37M21A*+ furnace: *97VTN1002122A*Cold climate designationAHRI reference: 218020447 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4568598 → |
EVD5X37M21A*+ furnace: OMV112K14ACold climate designationAHRI reference: 218020453 | 19.00 | 8.50 | 21800 | 1.90 | EPA 4568602 → |
EVD5X38M17A*+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 218020455 | 19.00 | 8.50 | 21800 | 1.90 | EPA 4568603 → |
EVD5X38M17A*+ furnace: *80VSL0451412B*Cold climate designationAHRI reference: 218020456 | 19.00 | 8.50 | 21800 | 1.92 | EPA 4568604 → |
EVD5X38M17A*+ furnace: *80VSL0701412B*Cold climate designationAHRI reference: 218020458 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4568605 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →