ACIQ / AIR-SOURCE HEAT PUMP

N5H8T60*K*AAA*

2-STAGE 18 SEER HP · source records, page 5

117 published source records · source checked Sep 21, 2026

SEER2 range15.5–17.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity54,000–57,500BTU/h

Each efficiency range summarizes published EPA records for N5H8T60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 117 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.5–17.5117 / 117
EER2 · BTU/Wh11.7–13117 / 117
HSPF2 · BTU/Wh7.8–8.5117 / 117
Cooling capacity · BTU/h54,000–57,500117 / 117
Heating capacity at 47°F / 8.3°C · BTU/h56,500–60,000117 / 117
Heating capacity at 17°F / −8.3°C · BTU/h36,200–38,500117 / 117
Heating capacity at 5°F / −15°C · BTU/h29,600–31,800117 / 117
COP at 5°F / −15°C2.1–2.34117 / 117
Equipment / loop typeHP - Split System117 / 117
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)117 / 117
Compressor stagingTwo-stage117 / 117
Connected capabilityNo117 / 117

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X60M24A*+ furnace: *80CTL1102120B*AHRI reference: 21663166916.008.00300002.25EPA 3961578 →
EA*5X60M24A*+ furnace: *80VTL0902120B*AHRI reference: 21663167116.008.00298002.25EPA 3961580 →
EA*5X60M24A*+ furnace: *95CSU1002122B*AHRI reference: 21663167416.008.00296002.30EPA 3961581 →
EA*5X60M24A*+ furnace: *97CMN0802120B*AHRI reference: 21663167616.008.00300002.25EPA 3961582 →
EA*5X60M24A*+ furnace: *96VSN1202422B*AHRI reference: 21663168116.008.00298002.25EPA 3961583 →
EA*5X60M24A*+ furnace: *96VSN0802120B*AHRI reference: 21663167916.008.00300002.25EPA 3961584 →
EA*5X60M24A*+ furnace: *96VSN1002120B*AHRI reference: 21663168016.008.00298002.25EPA 3961585 →
EA*5X60M24A*+ furnace: *97CMN1002122B*AHRI reference: 21663167716.008.00300002.25EPA 3961586 →
EA*5X60M24A*+ furnace: *80VTL1102122B*AHRI reference: 21663167216.008.00298002.30EPA 3961587 →
EA*5X60M24A*+ furnace: *96CTN1202422B*AHRI reference: 21663168616.008.00298002.25EPA 3961588 →
EA*5X60M24A*+ furnace: *96VTN0802120B*AHRI reference: 21663168716.008.00300002.25EPA 3961589 →
EA*5X60M24A*+ furnace: *96VTN1002120B*AHRI reference: 21663168816.008.00298002.25EPA 3961590 →
EA*5X60M24A*+ furnace: *96CTN1002122B*AHRI reference: 21663168516.008.00300002.25EPA 3961591 →
EA*5X60M24A*+ furnace: *95MSU1002120A*AHRI reference: 21663168316.008.00300002.25EPA 3961592 →
EA*5X60M24A*+ furnace: *95MSU1002122A*AHRI reference: 21663168416.008.00296002.30EPA 3961593 →
EA*5X60M24A*+ furnace: *96VTN1202422B*AHRI reference: 21663169016.008.00300002.25EPA 3961594 →
EA*5X60M24A*+ furnace: OLV154F20AAHRI reference: 21663169116.008.00302002.25EPA 3961595 →
EA*5X60M24A*+ furnace: *95MSU0802120A*AHRI reference: 21663168216.008.00300002.25EPA 3961596 →
EA*5X60M24A*+ furnace: *96VTN1002122B*AHRI reference: 21663168916.008.00296002.30EPA 3961597 →
EA*5X61M21A*+ furnace: *80VSL0902120B*AHRI reference: 21663169516.008.00300002.30EPA 3961599 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.