ACIQ / AIR-SOURCE HEAT PUMP

N5H8T60*K*AAA*

2-STAGE 18 SEER HP · source records, page 3

117 published source records · source checked Sep 21, 2026

SEER2 range15.5–17.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity54,000–57,500BTU/h

Each efficiency range summarizes published EPA records for N5H8T60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 117 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.5–17.5117 / 117
EER2 · BTU/Wh11.7–13117 / 117
HSPF2 · BTU/Wh7.8–8.5117 / 117
Cooling capacity · BTU/h54,000–57,500117 / 117
Heating capacity at 47°F / 8.3°C · BTU/h56,500–60,000117 / 117
Heating capacity at 17°F / −8.3°C · BTU/h36,200–38,500117 / 117
Heating capacity at 5°F / −15°C · BTU/h29,600–31,800117 / 117
COP at 5°F / −15°C2.1–2.34117 / 117
Equipment / loop typeHP - Split System117 / 117
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)117 / 117
Compressor stagingTwo-stage117 / 117
Connected capabilityNo117 / 117

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVD5X60M21A*+ furnace: *80MSU0802120A*AHRI reference: 21663153716.008.10304002.22EPA 3960551
EVD5X60M21A*+ furnace: *80MSU1002120A*AHRI reference: 21663153816.008.10304002.22EPA 3960552
EVD5X60M21A*+ furnace: *80VTL1102122B*AHRI reference: 21663154316.008.10304002.22EPA 3960554
EVD5X60M21A*+ furnace: *80CTL0902120B*AHRI reference: 21663154016.008.10304002.22EPA 3960555
EVD5X60M21A*+ furnace: *80VTL0902120B*AHRI reference: 21663154216.008.10304002.20EPA 3960556
EVD5X60M21A*+ furnace: *95CSU1002122B*AHRI reference: 21663154516.008.10306002.20EPA 3960557
EVD5X60M21A*+ furnace: *96VTN1002122B*AHRI reference: 21663155816.008.10302002.20EPA 3960558
EVD5X61M21A*+ furnace: *95MSU1002120A*AHRI reference: 21663160116.008.10314002.18EPA 3960559
EVD5X60M21A*+ furnace: *95MSU1002122A*AHRI reference: 21663155316.008.10302002.22EPA 3960560
EVD5X61M21A*+ furnace: *80VTL0902120B*AHRI reference: 21663159116.008.10310002.22EPA 3960561
EVD5X61M21A*+ furnace: *95CSU1002122B*AHRI reference: 21663159416.008.10308002.20EPA 3960562
EVD5X61M21A*+ furnace: *80MSU1002120A*AHRI reference: 21663158716.008.10310002.20EPA 3960563
EVD5X61M21A*+ furnace: *80MSU0802120A*AHRI reference: 21663158616.008.10306002.22EPA 3960564
EVD5X61M21A*+ furnace: *95MSU1002122A*AHRI reference: 21663160216.008.10310002.20EPA 3960565
EVD5X61M21A*+ furnace: *80VSL0902120B*AHRI reference: 21663158416.008.10310002.22EPA 3960566
EVD5X61M24A*+ furnace: *80VSL1352422B*AHRI reference: 21663161016.008.50318002.32EPA 3960567
EVD5X61M21A*+ furnace: *96VTN1002122B*AHRI reference: 21663160616.008.10308002.22EPA 3960568
EVD5X61M24A*+ furnace: *80MSU0802120A*AHRI reference: 21663161116.008.50316002.34EPA 3960569
EA*5X61M24A*+ furnace: *80VSL0902120B*AHRI reference: 21663172316.008.00300002.25EPA 3961118
EA*5X61M24A*+ furnace: *80CTL0702120B*AHRI reference: 21663172816.008.00306002.25EPA 3961120

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →