ACIQ / AIR-SOURCE HEAT PUMP

N5H8T60*K*AAA*

2-STAGE 18 SEER HP

117 published source records · source checked Sep 21, 2026

SEER2 range15.5–17.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity54,000–57,500BTU/h

Each efficiency range summarizes published EPA records for N5H8T60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 117 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.5–17.5117 / 117
EER2 · BTU/Wh11.7–13117 / 117
HSPF2 · BTU/Wh7.8–8.5117 / 117
Cooling capacity · BTU/h54,000–57,500117 / 117
Heating capacity at 47°F / 8.3°C · BTU/h56,500–60,000117 / 117
Heating capacity at 17°F / −8.3°C · BTU/h36,200–38,500117 / 117
Heating capacity at 5°F / −15°C · BTU/h29,600–31,800117 / 117
COP at 5°F / −15°C2.1–2.34117 / 117
Equipment / loop typeHP - Split System117 / 117
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)117 / 117
Compressor stagingTwo-stage117 / 117
Connected capabilityNo117 / 117

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
FTMA5B60L0D*AHRI reference: 21556191017.508.10302002.30EPA 3982845
EA*5X61M24A*+ furnace: *80MSU1002120A*AHRI reference: 21663172716.508.00302002.30EPA 3961116
EA*5X61M24A*+ furnace: *80VSL1102122B*AHRI reference: 21663172416.508.10298002.14EPA 3961117
EA*5X61M24A*+ furnace: *80CSU0802120A*AHRI reference: 21663172116.507.80314002.22EPA 3961119
EA*5X61M24A*+ furnace: *80CTL0902120B*AHRI reference: 21663172916.508.10302002.26EPA 3961121
EA*5X61M24A*+ furnace: *80MSU0802120A*AHRI reference: 21663172616.508.00298002.30EPA 3961122
EA*5X61M24A*+ furnace: *80VSL1352422B*AHRI reference: 21663172516.508.00300002.30EPA 3961123
EA*5X61M24A*+ furnace: *80CTL1352422B*AHRI reference: 21663173116.508.00302002.30EPA 3961124
EA*5X61M24A*+ furnace: *95CSU1002122B*AHRI reference: 21663173516.508.00300002.30EPA 3961125
EA*5X61M24A*+ furnace: *97CMN1002122B*AHRI reference: 21663173816.508.10304002.12EPA 3961126
EA*5X61M24A*+ furnace: *80VTL1102122B*AHRI reference: 21663173316.508.10300002.14EPA 3961127
EA*5X61M24A*+ furnace: *80CTL1102120B*AHRI reference: 21663173016.508.00302002.30EPA 3961131
EA*5X61M24A*+ furnace: *95MSU1002122A*AHRI reference: 21663174516.508.00302002.25EPA 3961134
EA*5X61M24A*+ furnace: *96VTN1002122B*AHRI reference: 21663175016.508.10298002.14EPA 3961141
EA*5X61M24A*+ furnace: OLV154F20AAHRI reference: 21663175216.508.00304002.25EPA 3961151
EA*5X60M24A*+ furnace: *80MSU0802120A*AHRI reference: 21663166516.508.00296002.30EPA 3961579
EA*5X61M21A*+ furnace: *80MSU0802120A*AHRI reference: 21663169816.508.00298002.30EPA 3961598
EA*5X61M21A*+ furnace: *80VSL1102122B*AHRI reference: 21663169616.508.10300002.12EPA 3961600
EA*5X61M21A*+ furnace: *80VTL1102122B*AHRI reference: 21663170516.508.00300002.30EPA 3961603
EA*5X61M21A*+ furnace: *80CTL1102120B*AHRI reference: 21663170316.508.00304002.25EPA 3961609

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →