ACIQ / AIR-SOURCE HEAT PUMP

N5H8T48*K*AAA*

2-STAGE 18 SEER HP · source records, page 7

389 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for N5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 389 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18389 / 389
EER2 · BTU/Wh11.7–13.5389 / 389
HSPF2 · BTU/Wh7.8–8.5389 / 389
Cooling capacity · BTU/h45,500–50,500389 / 389
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500389 / 389
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,600389 / 389
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600389 / 389
COP at 5°F / −15°C2.06–2.32389 / 389
Equipment / loop typeHP - Split System389 / 389
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)389 / 389
Compressor stagingTwo-stage389 / 389
Connected capabilityNo389 / 389

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVD5X61M24A*+ furnace: *95MSU0802120A*AHRI reference: 21663144616.508.10252002.12EPA 3960524 →
EVD5X61M24A*+ furnace: *96VTN1202422B*AHRI reference: 21663145516.508.10252002.12EPA 3960527 →
EVD5X61M24A*+ furnace: *96CTN0802120B*AHRI reference: 21663144916.508.10256002.10EPA 3960533 →
EVM5X49M21A*+TDRAHRI reference: 21663163416.508.00240002.15EPA 3960570 →
EVM5X60M21A*+TDRAHRI reference: 21663163516.508.00240002.15EPA 3960571 →
EVM5X48M21A*+ furnace: *80VSL1102122B*AHRI reference: 21663127016.508.10244002.14EPA 3960716 →
EVM5X48M21A*+ furnace: *80VSL0902120B*AHRI reference: 21663126916.508.10244002.12EPA 3960719 →
EVM5X48M21A*+ furnace: *80MSU1002120A*AHRI reference: 21663127316.508.10246002.12EPA 3960720 →
EVM5X48M21A*+ furnace: *80MSU0601716A*AHRI reference: 21663127116.508.10246002.12EPA 3960722 →
EVM5X48M21A*+ furnace: *80VTL0902120B*AHRI reference: 21663127716.508.10244002.12EPA 3960724 →
EVM5X48M21A*+ furnace: *95MSU1002120A*AHRI reference: 21663128516.508.10244002.12EPA 3960725 →
EVM5X48M21A*+ furnace: *95MSU1002122A*AHRI reference: 21663128616.508.10246002.12EPA 3960727 →
EVM5X48M21A*+ furnace: *80CTL0902120B*AHRI reference: 21663127516.508.10244002.14EPA 3960730 →
EVM5X48M21A*+ furnace: *80CTL1102120B*AHRI reference: 21663127616.508.10244002.12EPA 3960731 →
EVM5X48M21A*+ furnace: *80VTL1102122B*AHRI reference: 21663127816.508.10244002.14EPA 3960732 →
EVM5X49M21A*+ furnace: *80CTL0702120B*AHRI reference: 21663129716.508.10256002.08EPA 3960734 →
EVM5X48M21A*+ furnace: *96VTN1002122B*AHRI reference: 21663129116.508.10242002.12EPA 3960737 →
EVM5X49M21A*+ furnace: *96VSN0802120B*AHRI reference: 21663130716.508.10250002.12EPA 3960743 →
EVM5X49M21A*+ furnace: *95CSU0802120B*AHRI reference: 21663130216.508.10252002.10EPA 3960794 →
EVM5X49M21A*+ furnace: *96VSN1002120B*AHRI reference: 21663130816.508.10250002.10EPA 3960795 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →