ACIQ / AIR-SOURCE HEAT PUMP

N5H8T48*K*AAA*

2-STAGE 18 SEER HP · source records, page 14

389 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for N5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 389 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18389 / 389
EER2 · BTU/Wh11.7–13.5389 / 389
HSPF2 · BTU/Wh7.8–8.5389 / 389
Cooling capacity · BTU/h45,500–50,500389 / 389
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500389 / 389
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,600389 / 389
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600389 / 389
COP at 5°F / −15°C2.06–2.32389 / 389
Equipment / loop typeHP - Split System389 / 389
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)389 / 389
Compressor stagingTwo-stage389 / 389
Connected capabilityNo389 / 389

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X60M24A*+ furnace: *95CSU1002122B*AHRI reference: 21663185116.008.10256002.20EPA 3961178
EA*5X60M24A*+ furnace: *80VTL1102122B*AHRI reference: 21663184916.008.10256002.20EPA 3961179
EA*5X60M24A*+ furnace: *80CTL1352422B*AHRI reference: 21663184716.008.10260002.18EPA 3961181
EA*5X60M24A*+ furnace: *80VTL0902120B*AHRI reference: 21663184816.008.10258002.18EPA 3961184
EA*5X60M24A*+ furnace: *95MSU1002122A*AHRI reference: 21663186116.008.10256002.22EPA 3961186
EA*5X60M24A*+ furnace: *96CTN0802120B*AHRI reference: 21663186216.008.10260002.18EPA 3961187
EA*5X60M24A*+ furnace: *96VTN1002122B*AHRI reference: 21663186716.008.10254002.22EPA 3961191
EA*5X61M21A*+ furnace: *80CSU0802120A*AHRI reference: 21663187116.008.10254002.22EPA 3961194
EA*5X61M21A*+ furnace: *80CTL0702120B*AHRI reference: 21663188116.008.10262002.18EPA 3961206
EA*5X61M21A*+ furnace: *80VTL1102122B*AHRI reference: 21663188616.008.10254002.22EPA 3961208
EA*5X61M21A*+ furnace: *95CSU0802120B*AHRI reference: 21663188716.008.10260002.20EPA 3961209
EA*5X61M21A*+ furnace: *95MSU1002120A*AHRI reference: 21663189616.008.10256002.20EPA 3961211
EA*5X61M21A*+ furnace: *95CSU1002122B*AHRI reference: 21663188816.008.10256002.22EPA 3961212
EA*5X61M21A*+ furnace: *95MSU0802120A*AHRI reference: 21663189516.008.10256002.20EPA 3961214
EA*5X61M21A*+ furnace: *96VSN0802120B*AHRI reference: 21663189216.008.10256002.20EPA 3961215
EA*5X61M21A*+ furnace: *96VSN1002120B*AHRI reference: 21663189316.008.10258002.20EPA 3961216
EA*5X61M21A*+ furnace: *97CMN0802120B*AHRI reference: 21663189016.008.10258002.20EPA 3961218
EA*5X61M24A*+ furnace: *80MSU1002120A*AHRI reference: 21663190716.008.10262002.18EPA 3961219
EA*5X61M24A*+ furnace: *80VSL0902120B*AHRI reference: 21663190316.008.10260002.20EPA 3961220
EA*5X61M21A*+ furnace: *96VTN0802120B*AHRI reference: 21663190016.008.10256002.20EPA 3961221

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →