ACIQ / AIR-SOURCE HEAT PUMP

N5H8T48*K*AAA*

2-STAGE 18 SEER HP · source records, page 12

389 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for N5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 389 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18389 / 389
EER2 · BTU/Wh11.7–13.5389 / 389
HSPF2 · BTU/Wh7.8–8.5389 / 389
Cooling capacity · BTU/h45,500–50,500389 / 389
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500389 / 389
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,600389 / 389
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600389 / 389
COP at 5°F / −15°C2.06–2.32389 / 389
Equipment / loop typeHP - Split System389 / 389
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)389 / 389
Compressor stagingTwo-stage389 / 389
Connected capabilityNo389 / 389

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVD5X48M21A*+ furnace: *97CTN1002122A*AHRI reference: 21663518316.508.10244002.15EPA 3964860
EVD5X48M21A*+ furnace: *80CSU0802120B*AHRI reference: 21663518216.508.00240002.14EPA 3964861
EVD5X60M21A*+ furnace: *80CSU0401712B*AHRI reference: 21663518816.508.00246002.14EPA 3964864
EVD5X60M21A*+ furnace: *80CSU1002120B*AHRI reference: 21663519016.508.00246002.14EPA 3964866
EVD5X60M21A*+ furnace: *97VTN0802120A*AHRI reference: 21663519316.508.00248002.12EPA 3964867
EVD5X60M21A*+ furnace: *97VTN1002120A*AHRI reference: 21663519416.508.00246002.14EPA 3964870
EVD5X61M24A*+ furnace: *97CTN0802120A*AHRI reference: 21663520516.508.00256002.10EPA 3964871
EVD5X61M21A*+ furnace: *97CTN0802120A*AHRI reference: 21663519816.508.00252002.10EPA 3964877
EVD5X61M24A*+ furnace: *80CSU1002120B*AHRI reference: 21663520416.508.00250002.26EPA 3964881
EVD5X61M24A*+ furnace: *97VTN1202422A*AHRI reference: 21663521116.508.00252002.12EPA 3964883
EVM5X48M21A*+ furnace: *80CTL0702120B*AHRI reference: 21663127416.008.10248002.12EPA 3960717
EVM5X48M21A*+ furnace: *96CTN0802120B*AHRI reference: 21663128716.008.10252002.08EPA 3960726
EVM5X48M21A*+ furnace: *96VSN0802120B*AHRI reference: 21663128316.008.10248002.10EPA 3960728
EVM5X48M21A*+ furnace: *97CMN1002122B*AHRI reference: 21663128216.008.10246002.12EPA 3960729
EVM5X48M21A*+ furnace: *96VTN0802120B*AHRI reference: 21663128916.008.10248002.10EPA 3960733
EVM5X48M21A*+ furnace: *96CTN1002122B*AHRI reference: 21663128816.008.10246002.12EPA 3960739
EVD5X48M21A*+ furnace: *97CMN0802120B*AHRI reference: 21663135716.008.10244002.10EPA 3960839
EVD5X48M21A*+ furnace: *95CSU0802120B*AHRI reference: 21663135416.008.00246002.10EPA 3960842
EVD5X48M21A*+ furnace: *96VSN0802120B*AHRI reference: 21663135916.008.10244002.10EPA 3960849
EVD5X48M21A*+ furnace: *96CTN0802120B*AHRI reference: 21663136316.008.10244002.10EPA 3960850

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →