SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for N5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 389 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18389 / 389
EER2 · BTU/Wh11.7–13.5389 / 389
HSPF2 · BTU/Wh7.8–8.5389 / 389
Cooling capacity · BTU/h45,500–50,500389 / 389
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500389 / 389
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,600389 / 389
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600389 / 389
COP at 5°F / −15°C2.06–2.32389 / 389
Equipment / loop typeHP - Split System389 / 389
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)389 / 389
Compressor stagingTwo-stage389 / 389
Connected capabilityNo389 / 389

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVD5X60M21A*+ furnace: *96VSN0802120B*AHRI reference: 21663139816.508.10248002.12EPA 3960950
EVD5X60M21A*+ furnace: *95MSU0802120A*AHRI reference: 21663140016.508.10250002.12EPA 3960951
EVD5X60M21A*+ furnace: *95CSU0802120B*AHRI reference: 21663139516.508.10252002.10EPA 3960952
EVD5X60M21A*+ furnace: *96VTN1002120B*AHRI reference: 21663140416.508.10246002.14EPA 3960953
EVD5X61M21A*+ furnace: *80CTL0702120B*AHRI reference: 21663141116.508.10256002.08EPA 3960955
EVD5X60M21A*+ furnace: *96VTN0802120B*AHRI reference: 21663140316.508.10248002.12EPA 3960962
EVD5X61M21A*+ furnace: *95MSU0802120A*AHRI reference: 21663142216.508.10252002.10EPA 3960969
EVD5X61M24A*+ furnace: *80CTL0702120B*AHRI reference: 21663143416.508.10256002.10EPA 3960984
EVD5X61M24A*+ furnace: *97CMN1202422B*AHRI reference: 21663144216.508.10252002.12EPA 3960988
EVD5X61M24A*+ furnace: *95CSU0802120B*AHRI reference: 21663143916.508.10256002.08EPA 3960994
EA*5X60M24A*+ furnace: *80MSU0802120A*AHRI reference: 21663184216.508.10256002.20EPA 3961172
EA*5X61M21A*+ furnace: *80VSL0902120B*AHRI reference: 21663187416.508.10256002.22EPA 3961190
EA*5X61M21A*+ furnace: *80VSL1102122B*AHRI reference: 21663187516.508.10254002.22EPA 3961192
EA*5X61M21A*+ furnace: *80CTL0902120B*AHRI reference: 21663188216.508.10254002.22EPA 3961200
EA*5X61M21A*+ furnace: *80CTL1102120B*AHRI reference: 21663188316.508.10258002.20EPA 3961201
EA*5X61M21A*+ furnace: *80MSU0601716A*AHRI reference: 21663187616.508.10254002.22EPA 3961204
EA*5X61M21A*+ furnace: *80MSU1002120A*AHRI reference: 21663187816.508.10258002.22EPA 3961205
EA*5X61M21A*+ furnace: *80MSU0802120A*AHRI reference: 21663187716.508.10252002.22EPA 3961207
EA*5X61M21A*+ furnace: *80VTL0902120B*AHRI reference: 21663188516.508.10256002.22EPA 3961210
EA*5X61M21A*+ furnace: *97CMN1002122B*AHRI reference: 21663189116.508.10260002.20EPA 3961213

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.