ACIQ / AIR-SOURCE HEAT PUMP

N5H8T36*K*AAA*

2-STAGE 18 SEER HP · source records, page 7

249 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,800–37,600BTU/h

Each efficiency range summarizes published EPA records for N5H8T36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 249 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17249 / 249
EER2 · BTU/Wh11.7–13249 / 249
HSPF2 · BTU/Wh7.8–8.5249 / 249
Cooling capacity · BTU/h33,800–37,600249 / 249
Heating capacity at 47°F / 8.3°C · BTU/h37,200–39,000249 / 249
Heating capacity at 17°F / −8.3°C · BTU/h23,000–24,200249 / 249
Heating capacity at 5°F / −15°C · BTU/h17,500–19,600249 / 249
COP at 5°F / −15°C1.78–2.48249 / 249
Equipment / loop typeHP - Split System249 / 249
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)249 / 249
Compressor stagingTwo-stage249 / 249
Connected capabilityNo249 / 249

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X48M21A*+ furnace: *80VSL1102122B*AHRI reference: 21663222715.508.10191002.24EPA 3961909 →
EA*5X48M21A*+ furnace: *80CTL1102120B*AHRI reference: 21663223715.508.10191002.26EPA 3961910 →
EA*5X48M21A*+ furnace: *80CTL0902120B*AHRI reference: 21663223615.508.10190002.26EPA 3961913 →
EA*5X48M21A*+ furnace: *80VTL1102122B*AHRI reference: 21663224015.508.10191002.26EPA 3961915 →
EA*5X48M21A*+ furnace: *80VTL0902120B*AHRI reference: 21663223915.508.10192002.26EPA 3961917 →
EA*5X48M21A*+ furnace: *95MSU1002120A*AHRI reference: 21663225615.508.10191002.26EPA 3961918 →
EA*5X48M21A*+ furnace: *96VSN1002120B*AHRI reference: 21663225215.508.10193002.24EPA 3961919 →
EA*5X48M21A*+ furnace: *97CMN0802120B*AHRI reference: 21663224715.508.10191002.26EPA 3961923 →
EA*5X48M21A*+ furnace: *95CSU1002122B*AHRI reference: 21663224315.508.10190002.26EPA 3961924 →
EA*5X48M21A*+ furnace: *97CMN1002122B*AHRI reference: 21663224815.508.10191002.26EPA 3961925 →
EA*5X48M21A*+ furnace: *96VTN1002120B*AHRI reference: 21663226415.508.10191002.26EPA 3961927 →
EA*5X48M21A*+ furnace: *95MSU1002122A*AHRI reference: 21663225715.508.10190002.26EPA 3961928 →
EA*5X48M21A*+ furnace: *96CTN1002122B*AHRI reference: 21663226015.508.10191002.26EPA 3961930 →
ESH5X42M12A*+ furnace: *80MSU0802120A*AHRI reference: 21663231915.508.10190002.26EPA 3961941 →
EA*5X43M21A*+ furnace: *97CTN0802120A*AHRI reference: 21663514215.508.00193002.26EPA 3964819 →
EA*5X37M21A*+ furnace: *97CTN1002122A*AHRI reference: 21663513115.508.00193002.24EPA 3964821 →
EA*5X37M21A*+ furnace: *97VTN1002120A*AHRI reference: 21663513215.508.00193002.26EPA 3964825 →
EA*5X43M21A*+ furnace: *97CTN1002122A*AHRI reference: 21663514315.508.00193002.24EPA 3964830 →
EA*5X48M21A*+ furnace: *97CTN1002122A*AHRI reference: 21663514515.508.00191002.26EPA 3964832 →
EA*5X43M21A*+ furnace: *97VTN1002120A*AHRI reference: 21663514415.508.00192002.26EPA 3964834 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →