ACIQ / AIR-SOURCE HEAT PUMP

N5H8T36*K*AAA*

2-STAGE 18 SEER HP · source records, page 12

249 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,800–37,600BTU/h

Each efficiency range summarizes published EPA records for N5H8T36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 249 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17249 / 249
EER2 · BTU/Wh11.7–13249 / 249
HSPF2 · BTU/Wh7.8–8.5249 / 249
Cooling capacity · BTU/h33,800–37,600249 / 249
Heating capacity at 47°F / 8.3°C · BTU/h37,200–39,000249 / 249
Heating capacity at 17°F / −8.3°C · BTU/h23,000–24,200249 / 249
Heating capacity at 5°F / −15°C · BTU/h17,500–19,600249 / 249
COP at 5°F / −15°C1.78–2.48249 / 249
Equipment / loop typeHP - Split System249 / 249
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)249 / 249
Compressor stagingTwo-stage249 / 249
Connected capabilityNo249 / 249

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
ESH5X42M12A*+ furnace: *80CSU0802120A*AHRI reference: 21663230915.208.10192002.24EPA 3961934 →
ESH5X42M12A*+ furnace: *80VTL1102122B*AHRI reference: 21663233115.207.80190002.26EPA 3961935 →
ESH5X42M12A*+ furnace: *80VSL0902120B*AHRI reference: 21663231415.207.80191002.26EPA 3961936 →
ESH5X42M12A*+ furnace: *96VTN1002122B*AHRI reference: 21663235415.207.80188002.26EPA 3961937 →
ESH5X42M12A*+ furnace: *80MSU0601716A*AHRI reference: 21663231815.207.80190002.26EPA 3961938 →
ESH5X42M12A*+ furnace: *80VSL1102122B*AHRI reference: 21663231515.207.80190002.26EPA 3961939 →
ESH5X42M12A*+ furnace: *95CSU1002122B*AHRI reference: 21663233415.207.80190002.26EPA 3961940 →
ESH5X48M12A*+ furnace: *80MSU0802120A*AHRI reference: 21663236815.208.10190002.26EPA 3961942 →
ESH5X42M12A*+ furnace: OLV154F20AAHRI reference: 21663235615.208.10191002.26EPA 3961943 →
ESH5X48M12A*+ furnace: *80CTL0902120B*AHRI reference: 21663237415.208.10190002.26EPA 3961944 →
ESH5X48M12A*+ furnace: *80CTL1102120B*AHRI reference: 21663237515.208.10191002.26EPA 3961945 →
ESH5X48M12A*+ furnace: *80VSL0902120B*AHRI reference: 21663236315.208.10192002.24EPA 3961946 →
ESH5X48M12A*+ furnace: *80VSL1102122B*AHRI reference: 21663236415.208.10191002.26EPA 3961947 →
ESH5X48M12A*+ furnace: *80MSU0601716A*AHRI reference: 21663236715.208.10190002.26EPA 3961948 →
ESH5X48M12A*+ furnace: *80MSU1002120A*AHRI reference: 21663236915.207.80190002.26EPA 3961949 →
ESH5X48M12A*+ furnace: *95MSU0802120A*AHRI reference: 21663239215.207.80192002.26EPA 3961950 →
ESH5X48M12A*+ furnace: *97CMN1002122B*AHRI reference: 21663238515.208.10191002.26EPA 3961951 →
ESH5X48M12A*+ furnace: *95CSU1002122B*AHRI reference: 21663238115.208.10190002.26EPA 3961952 →
ESH5X48M12A*+ furnace: *80VTL0902120B*AHRI reference: 21663237815.208.10192002.24EPA 3961953 →
ESH5X48M12A*+ furnace: *80CTL1352422B*AHRI reference: 21663237615.208.10190002.26EPA 3961954 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →