ACIQ / AIR-SOURCE HEAT PUMP

N5H8T36*K*AAA*

2-STAGE 18 SEER HP · source records, page 10

249 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,800–37,600BTU/h

Each efficiency range summarizes published EPA records for N5H8T36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 249 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17249 / 249
EER2 · BTU/Wh11.7–13249 / 249
HSPF2 · BTU/Wh7.8–8.5249 / 249
Cooling capacity · BTU/h33,800–37,600249 / 249
Heating capacity at 47°F / 8.3°C · BTU/h37,200–39,000249 / 249
Heating capacity at 17°F / −8.3°C · BTU/h23,000–24,200249 / 249
Heating capacity at 5°F / −15°C · BTU/h17,500–19,600249 / 249
COP at 5°F / −15°C1.78–2.48249 / 249
Equipment / loop typeHP - Split System249 / 249
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)249 / 249
Compressor stagingTwo-stage249 / 249
Connected capabilityNo249 / 249

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X37M21A*+ furnace: *96CTN0801714B*AHRI reference: 21663212215.208.10196002.24EPA 3961839
EA*5X42M21A*+ furnace: *80VSL0902120B*AHRI reference: 21663213515.208.10189002.24EPA 3961844
EA*5X42M21A*+ furnace: *80VSL0901716B*AHRI reference: 21663213415.208.10188002.22EPA 3961845
EA*5X42M21A*+ furnace: *80VSL1102122B*AHRI reference: 21663213615.208.10188002.24EPA 3961848
EA*5X42M21A*+ furnace: *80CTL1102120B*AHRI reference: 21663214515.208.10188002.24EPA 3961849
EA*5X42M21A*+ furnace: *80CTL0902120B*AHRI reference: 21663214415.208.10189002.24EPA 3961850
EA*5X42M21A*+ furnace: *80MSU0601716A*AHRI reference: 21663213815.208.10188002.24EPA 3961851
EA*5X42M21A*+ furnace: *80CTL0901716B*AHRI reference: 21663214315.208.10189002.22EPA 3961852
EA*5X42M21A*+ furnace: *97CMN0802120B*AHRI reference: 21663215515.208.10188002.22EPA 3961853
EA*5X42M21A*+ furnace: *96VSN1002120B*AHRI reference: 21663216015.208.10190002.22EPA 3961854
EA*5X42M21A*+ furnace: *95CSU1002122B*AHRI reference: 21663215115.208.10189002.24EPA 3961855
EA*5X42M21A*+ furnace: *95MSU1002122A*AHRI reference: 21663216415.208.10188002.24EPA 3961856
EA*5X42M21A*+ furnace: *80VTL1102122B*AHRI reference: 21663214815.208.10188002.24EPA 3961857
EA*5X42M21A*+ furnace: *96CTN1002122B*AHRI reference: 21663216715.208.10188002.24EPA 3961858
EA*5X42M21A*+ furnace: *95MSU1002120A*AHRI reference: 21663216315.208.10188002.24EPA 3961859
EA*5X42M21A*+ furnace: *97CMN1002122B*AHRI reference: 21663215615.208.10188002.24EPA 3961860
EA*5X43M21A*+ furnace: *80CSU0401712A*AHRI reference: 21663217415.208.10196002.24EPA 3961863
EA*5X43M21A*+ furnace: *80CSU0802120A*AHRI reference: 21663217615.208.10195002.24EPA 3961868
EA*5X43M21A*+ furnace: *80CTL0701716B*AHRI reference: 21663218615.208.10195002.24EPA 3961869
EA*5X43M21A*+ furnace: *95CSU0601716B*AHRI reference: 21663219415.208.10194002.24EPA 3961878

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →