ACIQ / AIR-SOURCE HEAT PUMP

N5H8T24*K*AAA*

2-STAGE 18 SEER HP · source records, page 4

461 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for N5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 461 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5461 / 461
EER2 · BTU/Wh11.5–14461 / 461
HSPF2 · BTU/Wh7.8–8.5461 / 461
Cooling capacity · BTU/h22,200–25,000461 / 461
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400461 / 461
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000461 / 461
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500461 / 461
COP at 5°F / −15°C1.9–2.24461 / 461
Equipment / loop typeHP - Split System461 / 461
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)461 / 461
Compressor stagingTwo-stage461 / 461
Connected capabilityNo461 / 461

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X25M17A*+ furnace: *80CTL0701716B*AHRI reference: 21663246817.508.10111002.10EPA 3962020 →
EA*5X25M17A*+ furnace: *95CSU0601716B*AHRI reference: 21663247217.508.10111002.10EPA 3962021 →
EA*5X25M17A*+ furnace: *80VTL0451412B*AHRI reference: 21663247017.508.10110002.10EPA 3962022 →
EA*5X25M17A*+ furnace: *96VSN0801716B*AHRI reference: 21663247917.508.10111002.08EPA 3962025 →
EA*5X25M17A*+ furnace: *95MSU0601716A*AHRI reference: 21663248117.508.10111002.10EPA 3962027 →
EA*5X25M17A*+ furnace: *96VSN0601716B*AHRI reference: 21663247817.508.10112002.08EPA 3962028 →
EA*5X25M17A*+ furnace: *96CTN0601714B*AHRI reference: 21663248317.508.10111002.08EPA 3962030 →
EA*5X25M17A*+ furnace: *96CTN0801714B*AHRI reference: 21663248417.508.10111002.10EPA 3962032 →
EA*5X25M17A*+ furnace: OMV098J12*AHRI reference: 21663249117.508.10111002.10EPA 3962034 →
EA*5X25M17A*+ furnace: OMV112K14AAHRI reference: 21663249217.508.10115002.04EPA 3962036 →
EA*5X25M17A*+ furnace: *96VTN0801716B*AHRI reference: 21663248917.508.10111002.08EPA 3962038 →
EA*5X25M17A*+ furnace: *96VTN0601716B*AHRI reference: 21663248817.508.10112002.08EPA 3962040 →
EA*5X30M17A*+ furnace: *80MSU0601716A*AHRI reference: 21663250817.507.80109002.08EPA 3962056 →
EA*5X36M17A*+ furnace: *80VSL0451412B*AHRI reference: 21663253717.508.10109002.08EPA 3962219 →
EA*5X36M17A*+ furnace: *80VSL0701412B*AHRI reference: 21663253817.508.10109002.08EPA 3962224 →
EA*5X36M17A*+ furnace: *80MSU0601716A*AHRI reference: 21663254217.507.80109002.08EPA 3962227 →
EA*5X36M17A*+ furnace: *80MSU0401712A*AHRI reference: 21663254117.507.80109002.06EPA 3962228 →
EA*5X36M17A*+ furnace: *80VSL0701716B*AHRI reference: 21663253917.508.10110002.04EPA 3962229 →
EA*5X36M17A*+ furnace: *80VTL0451412B*AHRI reference: 21663254717.508.10109002.08EPA 3962235 →
EA*5X37M17A*+ furnace: *80VSL0701716B*AHRI reference: 21663257317.508.10112002.08EPA 3962254 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →